- Research
- Open access
- Published:
Effect of low climate impact vs. high climate impact inhalers for patients with asthma and COPD-a nationwide cohort analysis
Respiratory Research volume 25, Article number: 339 (2024)
Abstract
Background
Chronic obstructive pulmonary disease (COPD) and asthma can be treated with inhaled corticosteroids (ICS) delivered by low climate impact inhalers (dry powder inhalers) or high climate impact inhalers (pressurized metered-dose inhalers containing potent greenhouse gasses). ICS delivered with greenhouse gasses is prescribed ubiquitously and frequent despite limited evidence of superior effect. Our aim was to examine the beneficial and harmful events of ICS delivered by low and high climate impact inhalers in patients with asthma and COPD.
Methods
Nationwide retrospective cohort study of Danish outpatients with asthma and COPD treated with ICS delivered by low and high climate impact inhalers. Patients were propensity score matched by the following variables; age, gender, tobacco exposure, exacerbations, dyspnoea, body mass index, pulmonary function, ICS dose and entry year. The primary outcome was a composite of hospitalisation with exacerbations and all-cause mortality analysed by Cox proportional hazards regression.
Results
Of the 10,947 patients with asthma and COPD who collected ICS by low or high climate impact inhalers, 2,535 + 2,535 patients were propensity score matched to form the population for the primary analysis. We found no association between high climate impact inhalers and risk of exacerbations requiring hospitalization and all-cause mortality (HR 1.02, CI 0.92–1.12, p = 0.77), nor on pneumonia, exacerbations requiring hospitalization, all-cause mortality, or all-cause admissions. Delivery with high climate impact inhalers was associated with a slightly increased risk of exacerbations not requiring hospitalization (HR 1.10, CI 1.01–1.21, p = 0.03). Even with low lung function there was no sign of a superior effect of high climate impact inhalers.
Conclusion
Low climate impact inhalers were not inferior to high climate impact inhalers for any risk analysed in patients with asthma and COPD.
Introduction
Chronic obstructive pulmonary disease (COPD) and asthma can be treated with inhaled corticosteroids (ICS) delivered by low climate impact inhalers (dry powder inhalers) or high climate impact inhalers (pressurized metered-dose inhalers). High climate impact inhalers contain the potent group of greenhouse gasses hydrofluorocarbons causing a climate footprint approximately 20 times larger than with low climate impact inhalers [1,2,3]. No studies have been conducted in patients with both asthma and COPD comparing delivery of ICS by low and high climate impact inhalers, though ICS is a central part of the treatment of these patients. Patients with both asthma and COPD are in general not very well-characterized, especially in terms of treatment options, though they comprise a large group of patients worldwide.
The deposition pattern of pharmaceuticals delivered by low and high climate impact inhalers have been examined in small studies [4,5,6], and the clinical effects and risks of ICS delivered by low and high climate impact inhalers for patients with asthma without COPD and COPD without asthma has been analysed in randomized clinical trials (RCT)s [7,8,9,10,11,12,13,14,15,16] and epidemiological studies [17,18,19,20,21,22]. The results are inconsistent [7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22] with a possible increased effect [17,18,19,20,21] and risk [22] of ICS delivered by high climate impact inhalers. As no studies have depicted the effect and risk profile of ICS delivered by low and high climate impact inhalers for patients with both asthma and COPD, the aim of this study was to examine the beneficial and harmful effects of ICS delivered by low vs. high climate impact inhalers in patients with both asthma and COPD.
Our primary hypothesis was that treatment with ICS delivered by high climate impact inhalers was associated with fewer exacerbations requiring hospitalization and less all-cause mortality than low climate impact inhalers in patients with both asthma and COPD. This would reason the negative climate footprint of inhaler therapy for patients with concomitant asthma and COPD. Our secondary hypothesis was that treatment with ICS delivered by high climate impact inhalers was associated with more hospitalizations with pneumonia.
Methods
Study design
A nationwide retrospective cohort study was conducted by combining information from the following registries:
-
1.
The Danish Register of Chronic Obstructive Pulmonary Disease (DrCOPD): A nationwide database established in 2008 containing information on the quality of treatment of all patients with COPD treated by a respiratory medicine specialist at a Danish Hospital in an out-patient clinic [23]. Covariates included in this study were smoking status, dyspnoea assessed using the Medical Research Council (MRC) Dyspnoea Scale, BMI (body mass index) assessed as kilograms per square meter, and lung function assessed as forced expiratory volume in the first second as percent of predicted (FEV1%) [24].
-
2.
The Danish Civil Registration System: All citizens in Denmark acquire a unique personal identification number at birth or immigration. This unique personal identification number yields data on date of birth and gender, and links individual information for each resident in all Danish registries [25].
-
3.
The Danish National Health Service Prescription Database holds information on all prescriptions dispensed by Danish pharmacies since 1994 (coded according to ATC classification), including date of dispensation, quantity dispensed, strength, and formulation. All pharmacies are required by Danish legislation to provide information that ensures complete and accurate registration. [26]
-
4.
The Danish National Patient Registry holds information on all admissions to Danish hospitals since 1977, and hospital outpatient clinic visits since 1995. Each visit is coded by physicians with one primary diagnosis and one or more secondary diagnoses, according to the International Classification of Diseases, eighth revision (ICD-8) codes until 1994 and ICD-10 thereafter [27].
-
5.
The Danish Register of Cause of Death holds information on all deaths of citizens, who have died in Denmark since 1875 [28] coded according to ICD-8 classification until 1994 and ICD-10 thereafter.
Population
All Danish residents with a respiratory medicine specialist verified diagnosis of asthma (DJ45 or DJ46) and COPD (as registered in the DrCOPD database) seen in an outpatient clinic from January 1st, 2010, to March 14th, 2022 were included. Hence, the inclusion criteria were a diagnosis of asthma, a diagnosis of COPD and contact to an outpatient clinic. The diagnoses were registered by respiratory medicine specialists in relation to outpatient clinic contacts. Exclusion criteria were collection of ICS delivered by both high and low climate impact inhalers simultaneously, no collection of ICS, and one patient was excluded as his or her inhaler type could not be specified. We compared ICS delivered by low or high climate impact inhalers in patients with both asthma and COPD.
A patient’s study entry date was defined as 365 days after the date of their first collection of ICs delivered by a low or high climate impact inhaler, appendix I for an overview of ATC codes. All patients who collected ICS delivered by both formulations, were excluded. Only patients collecting ICs delivered by low or high climate impact inhalers were included in the propensity score matched cohort.
The patients who did not collect ICS treatment of any kind were included in the sensitivity analyses. In their case, study entry date could evidently not be their first collection of ICS, and hence their date of entry was defined as the date, when they had been treated and monitored by a respiratory medicine out-patient clinic for the same time frame, as the average patient collecting ICS.
The study period ran from January 1st, 2010, to March 14th, 2022 as we considered treatment and monitoring before 2010 dated and follow-up was limited to the time of conducted analysis (April 2023).
Baseline characteristics
All baseline characteristics were assessed from The Danish National Patient Registry and The Danish National Health Service Prescription Database.
Follow-up
Patients were followed for one year from study entry. This time frame served as the study period, during which patients were eligible to develop an event. There were no censoring criteria for the primary analysis, however for secondary analyses all-cause mortality was treated as a competing risk, except for the secondary analysis of all-cause mortality.
Outcomes
All outcomes were assessed for one year. During follow-up patients were followed for events of the primary outcome; composite outcome of exacerbations requiring hospitalization (admissions diagnosed as DJ44 Chronic obstructive pulmonary disease and all belonging subcodes as both A and B diagnoses) and all-cause mortality, and for secondary outcomes; admission with pneumonia (DJ13-DJ16, DJ170, DJ18, DJ2), all-cause mortality, all-cause admissions and exacerbations requiring prescriptions of prednisolone (ATC-code H02AB06 and H02AB07) but not admission. The outcomes were assessed from The Danish National Patient Registry, The Danish National Health Service Prescription Database and The Danish Register of Cause of Death.
Statistics
Patients treated with ICs delivered by low or high climate impact inhaler were propensity score matched on known and likely confounders; age (as a continuous variable), gender, tobacco exposure (divided into the categories “never smoking”, “passive smoking”, “previous smoking”, “active smoking” and “unknown tobacco exposure”), exacerbations requiring hospitalization in the year before study entry, MRC (with the options 1, 2, 3, 4 and 5), BMI (as a continuous variable), FEV1%, collected ICS dose and entry date. All variables for the propensity score match were assessed as close as possible to the entry date; for tobacco exposure the mean assessment took place 1 year and 4.8 months before study entry (IQR 4 years and 2.5 months – 0 years and 2.9 months); for MRC mean 1 year 5.1 months, CI 4 years 2.9 months – 0 years 3.0 months; FEV1% mean 1 year 5.6 months, CI 4 years 2.9 months – 0 years 3.1 months, and BMI mean 1 year 5.1 months, CI 4 years 2.5 months – 0 years 3.0 months. These variables are often, but not always updated at out-patient visits. Propensity score matching was performed using the Greedy Match algorithm from the Mayo Clinic [29].
Cox regression model and cumulative incidence curves with Grays analysis was used to assess the risk of events in the compared groups.
Some patients had more than one event during the follow-up period, and in this case only the first event was counted.
For the primary analysis unadjusted Cox regression model was employed.
For sensitivity analysis, we conducted an adjusted Cox proportional hazard regression model of the primary outcome in the unmatched population of all 10,947 patients with asthma and COPD; the 9,785 patients collecting ICS by low or high climate impact inhalers and 1,162 patients who did not collect ICS in the year before study entry. This analysis was adjusted for the variables included in the propensity score match (age, gender, tobacco exposure, exacerbations requiring hospitalization in the year before study entry, MRC, BMI, FEV1%, ICS dose and entry date). An additional analysis examined the most vulnerable group of patients with FEV1% < 30%.
Model control investigating the proportional hazards assumption was performed to validate the Cox proportional hazards regression, in all cases yielding p values > 0.05.
All statistical analyses were performed using SAS 9.4, Cary, NC, USA, and Microsoft Excel, Windows 365. A two-sided 95% confidence interval was considered statistically significant. Cumulative Incidence plots were customized by the NewSurv macro [30].
Results were presented as hazard ratios (HR) with 95% confidence intervals (CI).
Risks were visualized by cumulative incidence plots with Grays analyses. HR profiles of variables were visualized by forest plot.
Ethics
The study was approved by the Approval Committee of the Capital Region of Denmark by the Knowledge Centre for Data reviews (P-2022-952). In Denmark, retrospective use of register data does not require ethical approval or patient consent, hence, no patient consents were obtained. This access to data without patient consent is based on the inability to identify any real-life patient from data from the registries, as all data is completely anonymised. The research was conducted in accordance with the Declaration of Helsinki.
Results
We identified 106,199 patients with COPD diagnosed in relation to a hospital contact. Of these 57,093 were seen by a respiratory medicine specialist in an outpatient clinic, and of these 11,552 patients suffered from both asthma and COPD. Among the patients with specialist verified diagnoses of asthma and COPD 9,785 were treated with a quantifiable prescription of ICS by a low or high climate impact inhaler during 1st January 2010–14th March 2022. Hence, 49,106 patients were excluded as they were not seen in an outpatient clinic and hence did not have specialist verified diagnoses, and 45,541 were excluded as they suffered from COPD without asthma. Only two patients were excluded as they always received ICS delivered by both low and high climate impact inhalers. Further 1,764 were excluded as they did not receive ICS for a full year before entry. One patient was excluded as his or hers ICS could not be specified.
This yielded 9,785 patients available for analysis. They collected 65,697 prescriptions with maximum 69 collected ICS prescriptions for one patient in the 365 days before entry. Of the 9,785 patients, 3,904 collected ICS delivered by high climate impact inhalers and 5,881 patients collected ICs delivered by low climate impact inhalers. For the primary analysis only patients with all data on all variables included in the propensity score match were included (ICS by high climate impact inhalers: N = 3,532 and ICS by low climate impact inhalers: N = 5,077), Fig. 1.
Loss to follow-up
Loss to follow-up due to emigration from Denmark was seldom in all investigated groups: In total N = 5 patients in the primary analysis were lost to follow-up.
Baseline characteristics
Propensity score match yielded 2,535 + 2,535 comparable patients treated with ICS delivered by low and high climate impact inhalers, Table 1. Baseline variables were comparable among matching parameters; age 71.5 (ICS delivered by high climate impact inhaler) vs. 71.7 (ICS delivered by low climate impact inhaler), sex (61.5% female vs. 62.6%), tobacco exposure (35.8% active smokers vs. 36.0%), MRC (3 vs. 3), BMI (26 vs. 26), and GOLD FEV1% (15.9% stage 4 vs. 15.9%). Similarly comorbidities were very similar between the two groups; Charlson comorbidity index (4 vs. 4), hypertension (29.2% vs. 28.2%), diabetes (13.9% vs. 13.1%) and depression (4.4% vs. 3.9%) as examples. Treatment with other inhaled medicine were also comparable, 97.4% collected prescriptions of long-acting β2-agonist (LABA) among patients treated with ICS by delivered by high climate impact inhalers and 97.5% of patients treated with ICS by delivered by low climate impact inhalers collected LABA for example. Finally, exacerbations requiring admissions and exacerbations treated with prednisolone, but not requiring hospitalization were also similar (25.6% vs. 26.5% and 54.4% and 49.6% respectively).
Primary outcome analysis
Treatment with ICS delivered by high climate impact inhalers was not associated with a lower or higher risk of the primary outcome of exacerbations requiring hospitalization and all-cause mortality compared to ICS delivered by low climate impact inhalers (HR 1.02, CI 0.92–1.12, p = 0.77), Table 2 (unadjusted Cox analysis) and Fig. 2 (cumulative incidence plot) among propensity score matched patients.
Secondary outcome analysis
Treatment with ICS delivered by high climate impact inhalers was not associated with a higher or lower risk of hospitalization with pneumonia (HR 0.95, CI 0.83–1.09, p = 0.47), Table 2; Fig. 3.
Looking at the elements of the primary endpoint, ICS treatment with high climate impact inhalers was also not associated with an altered risk of all-cause mortality (HR 1.06, CI 0.90–1.25, p = 0.48), nor was risk of exacerbations requiring hospitalization (HR 1.01, CI 0.91–1.13, p = 0.85), or all-cause admissions (HR 0.94, CI 0.88–1.02, p = 0.14).
Risk of exacerbation requiring prescriptions but not hospitalization was associated to ICS delivered by high climate impact inhaler vs. ICS delivered by low climate impact inhaler with a HR of 1.10 (CI 1.01–1.21, p = 0.03).
Sensitivity analysis
Multivariable Cox regression and Forest plot on all patients with asthma and COPD including patients that did not receive ICS therapy.
A multivariable model analysing the primary outcome (exacerbations requiring hospitalisation and all-cause mortality) and adjusted for inhaler type, and the variables used in the match was performed on the 10,947 patients with all data available. These patients received ICS by high or low climate impact inhaler (9,785 patients), or did not receive ICS (1,162 patients). This yielded a HR of 0.99 for treatment with ICS delivered by high climate impact inhalers (CI 0.76–1.28, p = 0.93) and a HR of 0.89 for treatment with ICS delivered by low climate impact inhaler (CI 0.70–1.12, p = 0.31), Table 3; Fig. 4.
Analysis of the matching variables showed HRs of 1.28 (age group increasing risk for each decade, CI 1.23–1.34, p < 0.0001), 0.89 (sex decreased risk for men, CI 0.82–0.96, p < 0.0001), 1.49 (smoking history with increased risk, CI 1.23–1.80, p < 0.0001, however the group of never-smokers comprised only 651 individuals), 3.11 (exacerbations requiring hospitalisation in the year before entry, CI 2.85–3.38, p < 0.0001), and 1.29 (increasing severity of MRC, CI 1.24–1.34, p < 0.0001), 1.46 (increasing FEV1% GOLD stage, CI 1.39–1.54, p < 0.0001), 1.11 (low BMI, CI 1.02–1.21, p = 0.02), 0.95 (entry year with a slight drop in risk for each calendar year, CI 0.92–0.97, p < 0.0001), and finally, 0.85 (ICS dose before entry, CI 0.82–0.88, p < 0.0001).
Risk among patients with FEV1% < 30%
There was no interaction between ICS delivered by inhalers with different climate impact and low FEV1% (< 30%) in regard to the primary outcome, p for interaction: 0.68.
Discussion
ICS delivered by low climate impact inhalers was not associated to a higher risk of exacerbations requiring hospitalisation and all-cause mortality than ICS delivered by high climate impact inhalers. ICS delivered by low climate impact inhalers was also not associated to a higher risk of all-cause mortality, exacerbations requiring hospitalisation, or all-cause admission. ICS delivered by low climate impact inhalers was neither associated to a lower or a higher risk of admission with pneumonia. Finally, ICS delivered by high climate impact inhalers was associated to a slightly higher risk of exacerbations requiring a prescription of prednisolone without hospitalisation.
This is the first study comparing COPD exacerbation and death of ICS delivered by low and high climate impact inhalers in patients with both asthma and COPD. Our study is large, has complete follow-up, and available data for controlling several important confounders such at spirometry measures, tobacco history, MRC and BMI. Furthermore, we found no difference in safety profile depending on ICS delivered by low and high climate impact inhalers in patients with asthma and COPD, despite extensive theories on different anatomical deposition patterns, pharmacokinetic properties and device managing [4,5,6, 31]. This finding should be interpreted in the light of the extensive damage to the climate from high climate impact inhalers [1,2,3].
The patients in our primary analysis were very closely matched by nine clinical characteristics (age, gender, tobacco exposure, exacerbations requiring hospitalization, MRC, BMI, FEV1%, ICS dose and entry date) in order to minimize bias by indication.
Analyses of secondary outcomes similarly revealed no difference in safety profile for ICS delivered by low vs. high climate impact inhalers, with comparable HRs for pneumonia. The analysis on the effect of ICS delivered by high and low climate impact inhalers was elaborated by secondary outcome analyses on all-cause mortality, exacerbations requiring hospitalization or all-cause admission.
One outcome analysis did show an increased risk in patients treated with ICS delivered by high climate impact inhalers: exacerbations requiring prescriptions of prednisolone, but not hospitalization. However, the clinical relevance remains uncertain with a CI almost crossing one. We analysed hospitalisations with exacerbations and hospitalisations with pneumonia as well as exacerbations treated with prednisolone, but we did not analyse exacerbations of concomitant asthma and COPD treated only with antibiotics, as this is not a standard recommended treatment regimen when a patient also suffers from asthma, however, we may have missed some exacerbations / pneumonias not requiring hospitalisation in this context and a difference between groups cannot be ruled out in our study set-up.
A hypothesis has claimed that inhalation medicine delivered by high climate impact inhalers may be a better choice for patients with a low FEV1% [32,33,34,35,36,37]. Therefore, we conducted a sensitivity analysis in which we tested if there was an effect modulation between low FEV1% (GOLD FEV1% stage 4 with FEV1% < 30%) and effect on ICS delivered by low vs. high climate impact inhalers towards the primary outcome. However, this was not the case.
No studies have been performed on treatment with ICS delivered by different types inhaler in patients with both asthma and COPD, however our results are in line with RCTs performed on patients with asthma without COPD and COPD without asthma, which all showed no difference in disease control and safety profile in ICS delivered by high and low climate impact inhalers [7,8,9,10,11,12,13,14,15,16]. In contrast to the RCTs, most epidemiological studies in this field have pointed to an improved disease control [17,18,19,20,21] but also an increased risk of pneumonia [22] in patients treated with ICS delivered by high climate impact inhalers.
RCT studies on patients with asthma have shown equal effect and safety profile of ICS delivered by low and high climate impact inhalers in patients with asthma on bronchial hyperresponsiveness, quality-of-life scores, FeNO, spirometry test results, forced oscillation and time to first exacerbation [11,12,13,14,15,16], whereas epidemiological studies on patients with asthma showed an association between asthma control, reducing asthma exacerbations and FEV1 and treatment with ICS delivered by high climate impact inhalers [17,18,19, 38]. In patients with COPD, RCTs have shown similar effect on FEV1 [7], but epidemiological studies pointed to a superior effect of ICS delivered by high climate impact inhalers in controlling exacerbations of COPD [20, 21]. Some of the epidemiological studies comparing ICS delivered by low and high climate impact inhalers found a superior effect of ICS delivered by high climate impact inhalers in patients with either asthma or COPD, however this has not been shown for patients with both diseases. Further, several of these studies did not include clinical variables such as tobacco exposure, MRC, BMI and FEV1% in their analysis or match [17, 20, 21], one study switched patients from ICS delivered by low to ICS delivered by high climate impact inhalers at the discretion of the treating physician without matching or logistic regression analysis [18], and in one study the ICS treatment by high climate impact inhalers was compared to ICS treatment by low climate impact inhalers in unmatched groups [19]. In an epidemiological study showing an increased risk of pneumonia in patients with either asthma or COPD, matching was performed on only a limited number of variables, and not on important confounders like tobacco exposure, MRC, BMI and FEV1% [22].
Our study contributes to the accumulated evidence as both the first study on patients with concomitant asthma and COPD, but also as it is large and very well-matched in comparison to many of the other epidemiological studies done on ICS delivery by high and low climate impact inhalers.
Our study has strengths and limitations. Our study has a its large sample size, complete follow-up, and extensive data availability. The data available to us were extensive and for many patients complete including annually updated data on smoking status, FEV1%, MRC and BMI. Our analysis was based on all patients with COPD in an entire country; a population of > 100,000 patients with COPD, of whom almost 10,000 patients had concomitant asthma combined with relevant and quantifiable pharmacological treatment. In this context loss to follow-up was minimal (five patients in total), and the expected impact hereof on the results minimal.
As we were very keen on minimizing the risk of bias by indication, the propensity score matched groups for the primary analysis included only patients with all data available and the groups were matched very tightly on nine different variables. This was successful in generating very comparable groups even on unmatched variables such as co-morbidities evaluated in a hospital setting, which we also have full data availability on. Controlling for important confounders and successful propensity score matching is important to minimize bias by indication. However, our tightly matched groups might pose a challenge for the options for extrapolation of our study on a wider group of patients with asthma and COPD. Our results also appear robust on various outcomes and in both adjusted and unadjusted analyses.
As ICS use by low and high climate impact inhalers was only available to us as collected prescriptions, treatment adherence and inhalation technique were not captured, however since this is a large population, these factors (i.e. non-adherence and insufficient inhalation technique) are likely to be balanced between groups, and, in any case, our results reflect real-life use of both types of devices. We chose to include ICS dose in the matching variables based on collected ICS the previous year. Hence, patients who died just after they collected a first prescription of ICS, were not included and thus a risk of survivor bias cannot be dismissed.
When analysing ICS, it was not possible to consider the different molecule types, nor if delivery was ICS was delivered alongside other pharmaceuticals (LABA or long-acting muscarinic receptor antagonist (LAMA)), as matching or stratifying for these variables would have led to smaller populations for analysis and posed a risk for a type 2 error and a challenge with generalisability. Similarly, it was not possible to match or stratify for the many different types of low and high climate impact inhalers.
As our study is a retrospective cohort study, it has some inherent limitations regarding causality of the findings. However, our study is the first of its kind on the group of patients with both asthma and COPD, it is large and there was complete follow up. Despite the abundant availability of data, some variables were only available as semi-quantified data, and access to more complete data might have improved our analyses.
Future research could explore the development of environmentally friendly inhaler alternatives and assess their impact on patient outcomes and environmental sustainability. Longitudinal studies could also investigate the long-term effects of different inhaler therapies.
In conclusion, ICS delivered by low and high climate impact inhalers do not have different effect or safety profiles, even among patients with low pulmonary function (GOLD FEV1% stage 4 with FEV1% < 30%). In this light, there is no sign of a clinical benefit which could justify the climate footprint caused by high climate impact inhalers. Evidence-based decision-making should consider both patient outcomes and environmental considerations in inhaler selection.
Data availability
All data are available to anyone with genuiene interest though the national database forskermaskinen.
References
Janson C, et al. Carbon footprint impact of the choice of inhalers for asthma and COPD. Thorax. 2020;75(1):82–4.
Emeryk AW, et al. Impact of inhalers used in the treatment of respiratory diseases on global warming. Adv Respir Med. 2021;89(4):427–38.
Woodcock A, et al. Effects of switching from a metered dose inhaler to a dry powder inhaler on climate emissions and asthma control: post-hoc analysis. Thorax. 2022;77(12):1187–92.
Newman SP, et al. Comparison of beclomethasone dipropionate delivery by easyhaler dry powder inhaler and pMDI plus large volume spacer. J Aerosol Med. 2001;14(2):217–25.
Pitcairn G, et al. Deposition of corticosteroid aerosol in the human lung by Respimat Soft Mist inhaler compared to deposition by metered dose inhaler or by Turbuhaler dry powder inhaler. J Aerosol Med. 2005;18(3):264–72.
Hirst PH, et al. A comparison of the lung deposition of budesonide from Easyhaler, Turbuhaler and pMDI plus spacer in asthmatic patients. Respir Med. 2001;95(9):720–7.
Beeh KM, et al. Comparison of dry-powder inhaler and pressurized metered-dose inhaler formulations of Extrafine Beclomethasone Dipropionate/Formoterol Fumarate/Glycopyrronium in patients with COPD: the TRI-D Randomized Controlled Trial. Int J Chron Obstruct Pulmon Dis. 2021;16:79–89.
Ferguson GT, et al. Triple therapy with budesonide/glycopyrrolate/formoterol fumarate with co-suspension delivery technology versus dual therapies in chronic obstructive pulmonary disease (KRONOS): a double-blind, parallel-group, multicentre, phase 3 randomised controlled trial. Lancet Respir Med. 2018;6(10):747–58.
Ferguson GT et al. Budesonide/formoterol MDI with co-suspension delivery technology in COPD: the TELOS study. Eur Respir J, 2018. 52(3).
Ichinose M, et al. Long-term safety and Efficacy of Budesonide/Glycopyrrolate/Formoterol Fumarate Metered Dose Inhaler Formulated using Co-suspension Delivery Technology in Japanese patients with COPD. Int J Chron Obstruct Pulmon Dis. 2019;14:2993–3002.
Morice AH, et al. Therapeutic comparison of a new budesonide/formoterol pMDI with budesonide pMDI and budesonide/formoterol DPI in Asthma. Int J Clin Pract. 2007;61(11):1874–83.
Morice AH, et al. Comparable long-term safety and efficacy of a novel budesonide/formoterol pressurized metered-dose inhaler versus budesonide/formoterol Turbuhaler in adolescents and adults with asthma. Pulm Pharmacol Ther. 2008;21(1):32–9.
Morice AH, Andrews B, Taylor M. Comparison of the effect on bronchial hyperresponsiveness of beclomethasone dipropionate administered via a novel multidose dry-powder inhaler or a conventional pressurised metered dose inhaler. Respiration. 2000;67(3):298–305.
Muraki M, et al. Which inhaled corticosteroid and long-acting beta-agonist combination is better in patients with moderate-to-severe asthma, a dry powder inhaler or a pressurized metered-dose inhaler? Drug Deliv. 2017;24(1):1395–400.
Woo SD, et al. Efficacy and safety of a pressurized metered-dose inhaler in older asthmatics: comparison to a dry powder inhaler in a 12-Week randomized Trial. Allergy Asthma Immunol Res. 2020;12(3):454–66.
Hojo M, et al. Comparison of the clinical effects of combined salmeterol/fluticasone delivered by dry powder or pressurized metered dose inhaler. Pulm Pharmacol Ther. 2016;37:43–8.
Price D, et al. Device type and real-world effectiveness of asthma combination therapy: an observational study. Respir Med. 2011;105(10):1457–66.
Al-Ahmad M, Webb D. A prospective study of switching asthma patients from a fixed-dose combination (FDC) inhaled corticosteroid [ICS]/Long-Acting Beta agonist [LABA] therapy delivered by Dry Powder Inhaler (DPI) to ICS/LABA delivered by pressurised Metered Dose Inhaler (pMDI). Respir Med. 2022;194:106771.
Muller V, et al. Asthma control in patients receiving inhaled corticosteroid and long-acting beta2-agonist fixed combinations. A real-life study comparing dry powder inhalers and a pressurized metered dose inhaler extrafine formulation. BMC Pulm Med. 2011;11:40.
Jones R, et al. The comparative effectiveness of initiating fluticasone/salmeterol combination therapy via pMDI versus DPI in reducing exacerbations and treatment escalation in COPD: a UK database study. Int J Chron Obstruct Pulmon Dis. 2017;12:2445–54.
Wittbrodt ET, et al. Differences in health care outcomes between postdischarge COPD patients treated with inhaled corticosteroid/long-acting beta(2)-agonist via dry-powder inhalers and pressurized metered-dose inhalers. Int J Chron Obstruct Pulmon Dis. 2019;14:101–14.
Park JH, et al. Risk for pneumonia requiring hospitalization or emergency room visit according to delivery device for inhaled corticosteroid/long-acting beta-agonist in patients with chronic airway diseases as real-world evidence. Sci Rep. 2019;9(1):12004.
Lange P, et al. Danish Register of chronic obstructive pulmonary disease. Clin Epidemiol. 2016;8:673–8.
Miller MR, et al. Standardisation of spirometry. Eur Respir J. 2005;26(2):319–38.
Schmidt M, Pedersen L, Sorensen HT. The Danish Civil Registration System as a tool in epidemiology. Eur J Epidemiol. 2014;29(8):541–9.
Kildemoes HW, Sorensen HT, Hallas J. The Danish national prescription Registry. Scand J Public Health. 2011;39(7 Suppl):38–41.
Schmidt M, et al. The Danish National Patient Registry: a review of content, data quality, and research potential. Clin Epidemiol. 2015;7:449–90.
Helweg-Larsen K. The Danish Register of causes of Death. Scand J Public Health. 2011;39(7 Suppl):26–9.
Mayo. Department of quantitative health sciences mayo clinic research: http://bioinformaticstools.mayo.edu/research/gmatch/. 2022 [cited 2022 21.1].
Meyers J. NewSurv macrohttps://communities.sas.com/t5/SAS-Communities-Library/Kaplan-Meier-Survival-Plotting-Macro-NEWSURV/ta-p/479747, 2021.
Luczak-Wozniak K, et al. Mishandling of pMDI and DPI inhalers in asthma and COPD - repetitive and non-repetitive errors. Pulm Pharmacol Ther. 2018;51:65–72.
Adetiloye AO, et al. Effect of Chronic Obstructive Pulmonary Disease Severity on Inspiratory Flow Rates via Inhaler devices. West Afr J Med. 2023;40(9):989–96.
Lipworth BJ. Pharmacokinetics of inhaled drugs. Br J Clin Pharmacol. 1996;42(6):697–705.
Selroos O, Borgstrom L, Ingelf J. Performance of Turbuhaler((R)) in patients with Acute Airway obstruction and COPD, and in children with asthma: understanding the clinical importance of adequate peak Inspiratory Flow, High Lung Deposition, and low in vivo dose variability. Treat Respir Med. 2006;5(5):305–15.
Mehta N, et al. Comparing the efficacy and safety of salmeterol/fluticasone pMDI versus its mono-components, other LABA/ICS pMDIs and salmeterol/fluticasone Diskus in patients with asthma. Expert Opin Drug Deliv. 2015;12(6):963–75.
Basheti IA, et al. Associations between inhaler technique and asthma control among asthma patients using pressurised MDIs and DPIs. Int J Tuberc Lung Dis. 2016;20(5):689–95.
Capstick TGD, et al. Demystifying dry powder inhaler resistance with relevance to optimal patient care. Clin Drug Investig. 2024;44(2):109–14.
Park HS, et al. Real-life effectiveness of inhaler device switch from dry powder inhalers to pressurized metred-dose inhalers in patients with asthma treated with ICS/LABA. Respirology. 2019;24(10):972–9.
Acknowledgements
AGM was supported by the National Institute for Health and Care Research Manchester Biomedical Research Centre (NIHR Manchester BRC, NIHR203308) and by an NIHR Clinical Lectureship in Respiratory Medicine.
Funding
This study was funded by the Novo Nordisk Foundation (No. NNF20OC0060657).
Open access funding provided by Copenhagen University
Author information
Authors and Affiliations
Contributions
Conceptualization, B.B., P.S. and JU.S.J.; methodology, B.B., P.S., J.E., T.B.S., and JU.S.J.; software, B.B., P.S., and J.E.; validation, B.B. and P.S.; formal analysis, B.B.; investigation, B.B.; resources, P.S., J.E. and JU.S.J.; data curation, B.B. AND P.S.; writing—original draft prep-aration, B.B. , J.E., P.S. and JU.S.J.; writing—review and editing, B.B., P.S.,J.E., T.B.S., D.M, M.M., A.G.M., and JU.S.J; visualization, B.B., P.S. and JU.S.J.; supervision, JU.S.J.; project admin-istration, B.B.; funding acquisition, P.S. and JU.S.J. All authors have read and agreed to the pub-lished version of the manuscript.
Corresponding author
Ethics declarations
Consent for publication
All authors have consented to the publication of this publication.
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Bonnesen, B., Eklöf, J., Biering-Sørensen, T. et al. Effect of low climate impact vs. high climate impact inhalers for patients with asthma and COPD-a nationwide cohort analysis. Respir Res 25, 339 (2024). https://doi.org/10.1186/s12931-024-02942-8
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s12931-024-02942-8