Critical inhaler errors in asthma and COPD: a systematic review of impact on health outcomes

Abstract

Background

Inhaled drug delivery is the cornerstone treatment for asthma and chronic obstructive pulmonary disease (COPD). However, use of inhaler devices can be challenging, potentially leading to critical errors in handling that can significantly reduce drug delivery to the lungs and effectiveness of treatment.

Methods

A systematic review was conducted to define ‘critical’ errors and their impact on health outcomes and resource use between 2004 and 2016, using key search terms for inhaler errors in asthma and COPD (Search-1) and associated health-economic and patient burden (Search-2).

Results

Search-1 identified 62 manuscripts, 47 abstracts, and 5 conference proceedings (n = 114 total). Search-2 identified 9 studies. We observed 299 descriptions of critical error. Age, education status, previous inhaler instruction, comorbidities and socioeconomic status were associated with worse handling error frequency. A significant association was found between inhaler errors and poor disease outcomes (exacerbations), and greater health-economic burden.

Conclusions

We have shown wide variations in how critical errors are defined, and the evidence shows an important association between inhaler errors and worsened health outcomes. Given the negative impact diminished disease outcomes impose on resource use, our findings highlight the importance of achieving optimal inhaler technique, and a need for a consensus on defining critical and non-critical errors.

Background

Inhaled drug delivery is the cornerstone of therapy for the treatment of obstructive chronic airway diseases, such as asthma and chronic obstructive pulmonary disease (COPD) [1]. The most common devices used to administer aerosolized medication in day-to-day respiratory practice are the pressurized metered-dose inhaler (pMDI) and the dry powder inhaler (DPI). pMDIs are most often prescribed [2], but patients need to inhale correctly and coordinate breathing and actuation to ensure effective drug delivery [3,4,5,6]. In contrast, DPIs are breath-actuated, with most devices relying on a rapid and powerful inhalation manoeuvre for drug delivery, which can be particularly problematic for patients who struggle to inhale forcefully [6].

Recent advances in inhaler technologies have seen an explosion in the number of devices [7]. This plethora of devices, however, has led to confusion in their use amongst health-care providers (HCPs) and patients, who may not properly understand how to use inhalers [8]. Indeed, mastering an inhaler device involves correct preparation and handling of the device before inhalation, and an optimal inhalation technique; an error in any step of this process may lead to inadequate drug delivery to the lungs.

There is no one ‘perfect device’ and several studies have shown that inhaler technique errors made by patients with asthma and COPD are common in real life with both pMDIs and DPIs despite advances in inhaler device technology [3, 9,10,11,12]. Although study results vary, estimates of those making inhaler errors range up to 90% of patients irrespective of the device type used [13, 14]. Most importantly, it is vital to distinguish between ‘critical’ (sometimes defined as ‘essential’ or ‘crucial’) errors, which are likely to significantly impair the delivery of adequate medication to the lungs, and ‘non-critical’ errors, which are likely to result in a reduced amount of drug reaching the lungs compared with that attained using the correct technique [15, 16].

A recent major cross-sectional study of asthma patients has compared inhaler technique data with data on disease control, in order to determine which errors are most associated with poor health outcomes [17]. The results of this may provide the most coherent basis for defining and identifying critical errors; however, progress towards fully elucidating these errors is slow.

The societal and health-economic burden of poor inhaler technique is increasingly being recognised [10]. Worryingly, in three countries (the UK, Spain and Sweden) poor inhaler technique accounted for over €750 million in direct and indirect costs in 2015, for the two most commonly used DPIs [18]. These cost data, together with the increasing prevalence of obstructive lung diseases and restriction in healthcare spending is propagating the imperative need for inhaler competency (that is, correct and effective inhaler use) [15].

Recent global position documents from the Global Initiative for Asthma (GINA) and Global Initiative for Chronic Obstructive Lung Disease (GOLD) both give significant prominence to assessing and correcting poor inhalation technique before escalating drug therapy [19, 20].

Price et al. proposed the need for policy change and research focusing on current gaps in knowledge: specifically on the association between device errors and health economic and clinical outcomes, and on the patient characteristics associated with a higher frequency of errors [15]. Indeed, clinicians must recognise that the device itself and its characteristics are at least equally as important as the prescribed drug; and that in future, the choice of drug compound may be considered to be of secondary importance [3].

The aim of this study was to define ‘critical’ errors and their impact on health outcomes and resource use between 2004 and 2016. This was accomplished through systematically reviewing the scientific literature on inhaler errors made by patients when using pMDIs and DPIs, and the approaches used to assess them -- exploring the relationships between inhaler errors, disease outcomes, quality of life, and healthcare resource use, and associations between patient characteristics and inhaler errors. Given the striking variety of inhaler errors reported in the literature [11], this paper focuses on critical errors, as these are most likely to have a health impact.

Methods

Overview

This systematic review was undertaken in accordance with the methodological and reporting standards recommended by PRISMA [21], and was registered in the PROSPERO international prospective register of systematic reviews (CRD42016036118). The review consisted of two distinct searches: search-1 focused on definitions and descriptions of critical errors, and search-2 aimed to identify the literature regarding economic models on the cost of critical errors and patient burden (see Additional file 1: Table S1).

Inclusion criteria

Studies from search-1 were included if they reported data on inhaler errors with pMDI and/or DPIs in patients with asthma or COPD, and if they related inhaler technique to disease outcomes or quality of life (QoL). Studies from search-2 were included if they reported data on the patient and/or economic burden of inhaler errors. Soft-mist inhalers and nebulisers were not considered in either search, as pMDIs and DPIs are estimated to make up around 99.8% of the global market share of inhaler devices [22].

Both searches were conducted, reviewed, and each article checked, by two authors (LH, EF) in four online databases (Embase, Medline, EconLIT and Evidence-Based Medicine Reviews), limited to studies published in English between 2004 and May 2016. International conference proceedings from 2013 to 2016 were also scanned (see Additional file 1: Table S1). All the authors reviewed the finalized list of selected articles for approval.

Data extraction

The following data were recorded from each selected article: author and contact details; number of patients; patient characteristics including age, gender, education, comorbidities, socioeconomic class, concurrent device use, and previous instruction; type(s) of inhaler; type(s) of inhaler error(s); definition of critical error(s); type of disease (asthma, COPD, or both); and findings on disease outcomes or QoL.

We grouped the emergent themes into 5 domains in our systematic review; (1) patient characteristics, (2) educational aspects, (3) disease outcomes, (4) quality of life, (5) health economics. This qualitative assessment of the study results allowed results to be reported more clearly, in order to help explore the impact of critical errors on health outcomes and resource use.

When studies were examined for evidence of an association between patient characteristics and presence or rate of inhaler errors, an a priori predefined list of characteristics agreed by consensus between the authors was used to focus analysis. This included: patient age, gender, socioeconomic class, education level, inhaler education, comorbidities, and the number of inhaler devices prescribed at the same time.

Additionally, the reference lists of all retrieved papers were reviewed for any potentially relevant studies, and editorials, commentaries, case studies, letters and opinion pieces were excluded. Studies examining nebuliser inhaler errors or those pooling nebulizer inhaler errors data with data for other inhalers were excluded, as our aim was to assess inhaler devices that administer a single discrete dose. Studies that did not specify inhaler types were included, as it was considered likely that pMDIs and DPIs would have been used, due to these of inhaler types comprising the majority of market share [23]. Descriptive methods were used to analyse data for the associations mentioned above.

Results

Search results

Initially (not including grey literature), Search-1 yielded 114 studies: 62 of these were full-text articles and 52 were abstracts. Of these, five abstracts were identified as having an economics focus and were therefore moved to the results of Search-2 (Fig. 1). Following the addition of five grey literature abstracts, the total yield of Search-1 was again 114 studies.

Fig. 1
figure 1

PRISMA diagram. The database search and analysis in Search-1 initially yielded 114 full-text articles or abstracts; give abstracts were removed and incorporated into the results of Search-2 due to being economics-focused; a further five abstracts were added to Search-1 following the grey literature search. Therefore, the final yield of Search-1 was 114

All studies (n = 114) in Search-1 reported inhaler error data on pMDIs with or without spacers, and single- or multiple-dose DPIs (Fig. 2a and b). Study details including population age, respiratory disease, and inhaler device type are presented in Table 1.

Fig. 2
figure 2

a. Journal articles reporting critical inhaler errors for pMDIs and DPIs. Note: percentages are calculated as a proportion of total mentions (n = 105) of each inhaler type by all inhaler error studies. Individual studies may mention more than one inhaler type. b. Journal articles reporting critical inhaler errors for specific DPI device types, both multi-dose (blue) and single-dose (red). Note: percentages are calculated as a proportion of total mentions (n = 65) of all device types by all inhaler error studies. Individual studies may mention more than one inhaler type. c. Studies stating a definition of a critical error, separated into categories. Details of each study and the exact wording used by each are presented in Additional file 1: Table S4. Note: In this figure the term “critical error” refers to both critical errors and critical steps that, when performed incorrectly, constitute critical errors

Table 1 Journal articles (n = 63) and abstracts (n = 60) identified within the literature search

Search-2 on the health-economic burden of inhaler errors yielded only one full-text article and three abstracts that fulfilled the inclusion criteria, to which five abstracts from Search-1 were added (Fig. 1).

Definition of critical inhaler errors

Among the 36 studies giving specific examples of ‘critical’ errors, 32 included a definition of ‘critical’ inhaler errors, and the definition itself substantially varied between the studies (Fig. 2c). In most cases, studies did not provide information on the origin of their definition of a critical error; however, where this information was provided, definitions were commonly taken from previous studies, rather than being formulated by the study researchers. Astonishingly, our search yielded 299 descriptions of critical errors across the device types.

The most common definition was an action affecting the lung deposition of inhaled drug, resulting in little or no medicine being inhaled or reaching the lungs (n = 27), where 14 definitions stated a critical error “would” certainly affect inhalation and drug delivery [24,25,26,27,28,29,30,31,32,33,34,35,36,37], and 13 others said a critical error “could” affect these [38,39,40,41,42,43,44,45,46,47,48,49,50]. Conversely, 4 papers defined a critical error in terms of effectiveness: that is, an error that would make aerosol therapy useless [10, 51,52,53]; and Pascual used a combined definition of deposition and effectiveness: that is, “an error that compromised the potential benefit of the treatment, such as impeding drug deposition or the delivery of an insufficient dose” [54].

Surprisingly, only sixty studies (53%) used a checklist to quantify errors and to enable comparisons between devices. However, these checklists were often created by the authors themselves (either taken from previous studies, or were copied from the instructions provided with the inhaler device), without external validation of the checklist itself for each device type. The number of critical errors described varied by device type and by study (Additional file 1: Table S2).

To further compound matters, there were also differences in the descriptions of the actual errors themselves. For example, one DPI error was described in four different ways: two studies mentioned the critical steps which, if not performed, would be errors: “slide lever as far as possible” [42]; “push lever back completely” [27]; and two gave differing terminology for the critical error: “failure to slide the lever until the ‘click’ sound” [51] and “not sliding back the lever until a click is heard” [30]. Similarly, there were also differences in agreement between the authors of the different studies in the categorization of a critical error versus a non-critical error, once again affecting attempts to compare studies and collectively understand the impact of inhaler errors in daily clinical practice. For example, not holding the inhaler upright whilst using a pMDI was referred to as a critical error or step by three studies [39, 42, 44], but Bryant defined it simply as an “error” [55].

While many studies reported associations between characteristics or patient experiences and errors, these did not specify whether associations existed with critical errors specifically, or with all errors.

Effects of patient characteristics on frequency of inhaler errors

Overall, 41 studies of 114 (36%) investigated the effect of predefined patient characteristics on inhaler error frequency (Table 1), with patient age, gender, level of education, number of devices prescribed, and previous inhaler instruction being the most commonly explored factors.

Of 33 studies which examined the effect of patient age [10, 26, 30, 33, 34, 38, 40, 44, 48, 53, 55,56,57,58,59,60,61,62,63,64,65,66,67,68,69,70,71,72,73,74,75,76,77], 29 were in adults and 4 were paediatric. Only twelve studies (36%) reported age to be significantly associated with worsening frequency of inhaler errors [10, 26, 30, 44, 53, 57, 60, 64, 66, 69, 72, 73], whereas 21 studies found no significant association. In 7 studies, older adults were found to make significantly more errors [10, 30, 44, 57, 60, 64, 66]. Of the 4 paediatric studies [26, 40, 53, 74], two reported a significant association between age and frequency of errors: Deerojanawong reported that younger children made errors significantly more frequently [26], while Capanoglu reported the opposite finding: that older children made errors more frequently [53]. Twenty-five studies of 114 (22%) reported on the effects of gender [10, 30, 34, 38, 40, 44, 48, 53, 55, 56, 59,60,61, 63, 65,66,67, 70, 73, 74, 76,77,78,79,80], where 6 studies concluded a significant impact on inhaler error frequency, but the results were contradictory and inconclusive as to whether male or female gender was associated with poor technique [48, 53, 60, 66, 79, 80]. Of the 22 studies that reported a trend between low education and high inhaler error frequency [10, 34, 38, 44, 48, 53, 56, 59,60,61,62, 64,65,66,67, 70, 73,74,75,76, 80, 81], 10 found the association to be statistically significant [10, 34, 48, 53, 56, 60, 62, 66, 73, 80].

Of the 114 articles, 21 studies (18%) explored the relationship between previous inhaler instruction and inhaler error frequency [10, 25, 26, 30, 36, 39, 40, 44, 48, 53, 61, 62, 66,67,68, 71, 72, 74, 76, 80, 81], where 11 studies found previous education or instruction to be significantly related to better inhaler technique [10, 36, 39, 44, 48, 53, 61, 66, 68, 76, 80]. One study by Al-Jahdali reported a significant relationship between ‘lack of education about medication’ and improper device use [67], and two reported that reduced error frequency among previously instructed patients was dependent on device type, where technique improved only in patients using MDI spacer [26] or Diskus or Turbuhaler. [30] Interestingly, a third of studies (n = 7) reported that previous instruction in inhaler use did not significantly affect inhaler technique [25, 40, 62, 71, 72, 74, 81].

Specifically, we noted a statistically significant relationship was reported between increased error frequency and other patient characteristics such as having the presence of two or more comorbidities [56], obesity [48], heart disease [80], cognitive impairment or neuropathy [79], and lower socioeconomic class [56]. There were contradictory results between three studies that reported significant results for whether a higher or lower number of devices prescribed concurrently impacts error frequency [25, 44, 82].

Effects of educational intervention on frequency of inhaler errors

Educational interventions and their relationship to inhaler errors were addressed in 52 articles [27,28,29, 34, 37, 39, 45, 49,50,51, 54, 57,58,59, 61, 83,84,85,86,87,88,89,90,91,92,93,94,95,96,97,98,99,100,101,102,103,104,105,106,107,108,109,110,111,112,113,114,115,116,117,118,119], but studies varied in how errors were assessed (the tools used), by whom (the healthcare personnel), and in the duration of intervention. Interventions were undertaken by face-to-face consultation with a variety of HCPs involving physicians (n = 5), nurses (n = 5), paramedics (n = 1), and pharmacists (n = 8). In other studies, a video (n = 5), leaflet instructions (n = 17), or an online program were used (n = 2). Thirty-two studies undertook patient assessments before and after the educational intervention [29, 34, 39, 45, 51, 57,58,59, 61, 83,84,85,86,87,88,89,90,91,92, 94, 95, 97, 100,101,102,103,104, 108, 109, 114, 115]. Where 26 studies positively reported a significant improvement in inhaler technique following the intervention [29, 34, 39, 51, 57, 58, 61, 83,84,85,86,87,88,89, 92, 94, 95, 97, 101, 103, 104, 108, 109, 114, 115].

Analysis of interventions noted that the majority of the pharmacist-led studies, seven of the eight, demonstrated a statistically significant improvement in inhaler technique [39, 61, 84, 87, 91, 101, 103]. Of the five nurse-led interventions [34, 58, 85, 90, 99], three succeeded in significantly improving inhaler technique [34, 58, 85], and two reported a decrease in inhaler error frequency but did not include a statistical analysis [90, 99]. A further six HCP studies reported statistically significant improvements: three physician-led interventions, a physician-and therapist-led study, GP assistant study and a paramedic-led study all reported statistically significant improvements [57, 83, 89, 92, 94, 97]. Four studies with unspecified instructor types reported improvement [45, 51, 95, 102], but only two provided statistical analysis [51, 95]. Of the leaflet-based intervention studies (n = 17) [27,28,29, 37, 45, 49, 50, 54, 88, 93, 104, 106, 107, 112, 115, 118, 119], five compared inhaler technique before and after the intervention, of which four reported a significant improvement in inhaler technique [29, 88, 104, 115].

Association between disease outcomes and inhaler errors

Thirty-six of the 114 studies (Table 1) examined disease outcomes in relation to inhaler errors or inhalation technique (see Table 2 for a summary of available odds ratios). In the assessment of asthma control, the most common measurements were the Asthma Control Questionnaire (ACQ) and Asthma Control Test (ACT) instruments. [120, 121] Other measurements included: the Control of Allergic Rhinitis and Asthma Test [122], Asthma Therapy Assessment Questionnaire [123], Test For Respiratory And Asthma Control In Kids scales [124], frequency of exacerbations, emergency healthcare use, or general classification of patients into levels of disease control using the Global Initiative for Asthma (GINA) criteria. For COPD patients, disease outcomes were measured by: Baseline Dyspnoea Index (BDI), rates of exacerbations, hospitalizations, or by degree of dyspnoea using the modified Medical Research Council (MRC) questionnaire.

Table 2 Published odds ratios for baseline associations between poor inhaler technique and poor disease control

Our systematic analysis revealed 10 studies observed a higher inhaler error frequency was significantly associated with poor disease outcomes, primarily in asthma (n = 9), but also in asthma and COPD (n = 1) [10, 38, 48, 53, 56, 57, 67, 78, 90, 97, 117]. Molimard reported that using a device incorrectly, irrespective of the type, was associated with an increased Asthma Control Score [42], and in another study by Kuprys-Lipinska and Wiacek, over 94% of patients reported an association between improved DPI technique and better disease outcomes in asthma and COPD; however, no statistical analysis was provided [100, 109]. Groot reported that incorrect inhaler technique with unspecified inhalers was the underlying cause of poor asthma control in 7.8% of its population, but again did not provide statistical analysis [125].

We identified eight studies where the inhaler training interventions (including such aspects as physical demonstration, technique labels, and written action plans) led to an improvement in inhaler technique and also a significant increase in disease control, (seven in asthma [39, 83, 84, 87, 94, 96, 111], and one in COPD [88]) while 4 studies reported that their intervention significantly improved disease outcomes or reduced hospital admission frequency, but did not measure inhaler error frequency [98, 105, 116, 117]. Two further studies reported that training significantly improved technique and outcomes in asthma, but not in COPD patients [68, 104]. Eight studies reported no significant relationship between poor inhaler technique or errors with asthma control [34, 40, 58, 59, 70, 86, 89, 126].

Association between quality of life and inhaler errors

Seven of the 114 studies examined any association between QoL and inhaler errors: three in asthma, two in COPD and two in a mixed population.

A significant improvement in QoL was reported in three studies, following interventions which improved inhalation technique [84, 88, 91]. Basheti observed a significant correlation between improvement in DPI technique and improvement in asthma-related QoL following a pharmacist-led training intervention [84]. Goris reported significant improvements in QoL according to the St. George’s Respiratory Questionnaire (SGRQ) in all domains of QoL following intervention (aided by a movie and leaflet) in pMDI and DPI technique in COPD patients [88]. Maazuddin reported a pharmacist-led intervention led to significant improvements in the SGRQ outcomes in patients with COPD for pMDI and aerosol based devices including, Autohaler® and Evohaler®, but not for the three DPIs Revolizer®, Rotahaler® and Starhaler® [91].

A further study by Plaza reported a clinically significant increase in Mini Asthma Quality of Life Questionnaire scores among patients receiving a repeated training intervention (including development of a personalised action plan) delivered by a professional educator, physician or nurse, but the inhaler error frequency was not captured [98].

In contrast, an RCT by Hesselink found no significant impact on QoL in asthma and COPD (measured using the Quality-of-Life for Respiratory Illness Questionnaire) following a family practice assistant intervention (involving a structured consultation and use of checklist), although a significant improvement in inhaler technique was recorded [89]. An observational, retrospective study by Takemura reported unchanged SGRQ scores in asthma patients following intervention at regular intervals of at least 6 months by certified participants in a community-pharmacist educational program [103]. A further study by Pothirat captured a non-significant relationship between inhaler errors and poor quality of life, as judged by the by COPD Assessment Test (CAT) [34].

Economic models investigating the costs associated with inhaler errors

Our analysis identified eight studies [127,128,129,130,131,132,133,134,135], of which one was reported both in manuscript and abstract form [127, 128].

Roggeri reported a modelling study conducted in Italy and calculated the increased healthcare resource use by asthma or COPD patients making one or more critical inhaler error and showed this was associated with an additional yearly cost of €44,104 (asthma) or €23,444 (COPD) per 100 patients [127, 128]. Contextualising this for COPD, 100 patients making at least one inhaler error would require 11.5 additional hospitalisations, 13 emergency room visits, 19.5 courses of antimicrobials, and 47 courses of oral corticosteroids, compared to 100 patients not making any critical errors. Corresponding figures for 100 asthma patients were 19 hospitalisations, 26.5 emergency room visits, 4.5 antimicrobial courses and 21.5 oral corticosteroid courses [127, 128].

Bijos modelled the impact of poor inhaler technique on healthcare resource use in Poland, and concluded that misuse of inhaled corticosteroid and long-acting beta agonist fixed-dose combinations resulted in an annual loss of 378 million PLN (€91.1 million) in direct costs and 20.4 million PLN (€4.9 million) in indirect productivity, costs across asthma and COPD [129].

Torvinen calculated the effect on disease outcomes and the economic impact of a new DPI inhaler reported to reduce inhalation errors through innovative inhaler characteristics, and showed a potential saving of €57.78 million, based on a 10.1% rate of uptake among 701,983 patients with persistent asthma or COPD in Italy when switching to the new device from their existing DPI inhalers of Turbuhaler® or Diskus®, by year 5 of the model [130].

In the UK, Lewis considered the impact of inhaler errors on the economic burden of asthma and COPD with inhaled corticosteroid/long-acting beta-agonist (ICS/LABA) fixed-dose combinations [131]. The authors estimated that 366,000 of the 1.3 million persistent asthma/COPD patients within the UK have poor inhalation technique, and that this was associated with 11.8% (£16.2 million) of unscheduled health care events per year [131].

In a further study, Lewis estimated the additional resource use due to poor inhalation technique in Spain, and calculated a loss of €11.54 million due to unscheduled healthcare events among 563,562 asthma and COPD patients using Turbuhaler® or Accuhaler®. [132] Two similar economic models considered the impact of improved inhalation technique in asthma and COPD and in the UK and Sweden, and concluded that improved technique could save £3.5 million in the UK through reducing the number of unscheduled health events (assuming an update of 25% in years 4 and 5 of the model), and SEK285.4 million (€31.2 million) in Sweden by reducing the number of lost working days [133, 134].

Of note, four out of the 9 studies were related to the same device utilised in studies sponsored by the same company within a year of each other using the same health economic model employing a device switch approach to the study design [130, 132,133,134].

Conversely, a real world study in COPD (n = 108) conducted in Colombia reported that making inhaler errors was associated with a minor increase in monthly cost per patient ($146.9, versus $142.2 for other patients) [135].

Interestingly, no economics-focused studies on a US population were captured.

Generic issues identified

As previously mentioned, several types of inconsistency or heterogeneity between captured studies were seen during the review – each of which made the analysis of the data challenging.

The inconsistency in defining critical errors versus normal errors makes drawing conclusions on associations difficult, as errors were considered critical or non-critical by different researchers using different definitions; this is an important issue identified throughout the systematic review.

Furthermore, as differing checklists were used, containing differing numbers and descriptions of errors, error frequencies are likely not completely comparable between studies. In addition, “poor technique” was defined differently by different researchers, who commonly used differing thresholds for labelling a patient’s technique as incorrect or poor [55, 56].

In addition, although disease outcomes were captured using known measures of control, the variety of different measures used does make it more difficult to draw firm conclusions on the association between error frequency and asthma control.

Discussion

The aim of our article was to define ‘critical’ inhaler errors and their impact on health outcomes and resource use; and by doing so, to bring to the attention of physicians the importance of the inhaler device in their daily prescribing in the management of patients with asthma and COPD. Indeed, both GINA and GOLD now highlight the critical importance of assessing inhaler technique to guide appropriate inhaler prescribing, with a concerted drive to educate professionals and patients about the real impact of inhaler errors on the patients’ disease control, as well as on the financial economics of societal health.

To our knowledge this is the first formally registered evidence-based systematic review with a priori clearly formulated questions that documents the wide discrepancies within the literature regarding definitions and descriptions of inhaler errors and their classification as either ‘critical’ or ‘non-critical’. Previous reviews such as that by Basheti et al. focusing on inhaler error checklists have approached these issues [136], although in a different context.

Astonishingly, we observed 299 different descriptions of critical inhaler errors. Even for the same inhaler device type, different terminology was used between different study authors to describe the same inhaler error, and this may contribute to the confusion observed in clinical practice with regards to best inhaler practice and the limitations in determining associations with inhaler errors [8]. This heterogeneity and lack of consensus fundamentally hampers the ability to interpret studies with respect to the impact of inhaler errors. Indeed, the different definitions of critical error could be a contributing factor to extremely different conclusions even with the same inhaler device type; as exemplified in the Melani study where MDI users were significantly less likely to commit critical errors relative to DPI users [10], in contrast to the Batterink study where MDI users were most likely to make critical errors [25].

The lack of consensus between researchers extends to the use of differing inhaler technique checklists. As the checklists used are not standardized, even within individual inhaler device types, comparing error rates between or within inhaler device types is unfeasible. Future research can and should adopt more consistent inhaler technique checklists, as the manufacturers’ instructions are available to form a basis for a checklist in almost all cases.

We observed several important factors, including older age, education status, lack of previous inhaler instruction, and lower socioeconomic class, which were all associated with high inhaler error frequency. In addition, inhaler technique interventions were found to decrease error frequency, and have positive impacts on disease and patient outcomes, as has previously been described in the literature by Basheti et al. [137].

However these findings were not reflected in all studies, likely due to differences in study design and populations. For example, both interventional and observational studies were included, there were different inhaler devices included (i.e. pMDI or DPI), and wide ranging population sizes (between 46 and 6512 individuals), thereby limiting our ability to directly compare the results.

Interestingly, a significant association with error frequency was found for some comorbidities that are known to be strongly correlated with age, such as obesity, heart disease, or cognitive impairment [48, 79, 80]; but despite this, only around a third of studies that examined age itself reported a significant association with error frequency.

Our systematic review identified studies showing an association between inhaler errors and poor asthma control and COPD disease stability. This is in line with a recent individual study that has demonstrated that inhaler errors affect drug delivery [138]. Sulaiman showed in a laboratory environment that deliberately making certain inhaler errors led to a reduced amount of drug reaching the bloodstream [138]. However, the limited quantity of disclosed research in this area may suggest that the term “critical” is being overused, with only a weak basis for categorising errors as such.

In a recent real-world study by Molimard in 2935 patients an increased risk of COPD exacerbation among patients who made a critical inhaler error, was confirmed [139]. A further study by Price determined that the error of “insufficient respiratory effort” was associated with increased asthma exacerbation rate, as well as decreased control in general [140].

Importantly, we identified eight economic models which linked inhaler errors to economic burden, of which one study by Roggeri demonstrated a specific link between critical errors and resource use, leading to an excess cost of many thousands of Euros per 100 patients making critical errors [127, 128]. Indeed, recently Lewis and colleagues showed that poor inhalation technique led to approximately ¾ billion euros in direct and indirect costs for just two DPI inhalers used over 1 year [18].

Previous literature has also demonstrated that poor disease outcomes are linked with worsened QoL and increased resource use and economic burden through increased physician consultation time and lost productivity (Additional file 1: Table S3) [141,142,143,144,145,146]. Therefore, the issue of inhaler errors is important to address due to the downstream effects on patients, healthcare systems and society.

Our findings clearly illustrate inhaler technique can be affected by the level of instruction from HCPs. It is therefore important to interpret clinical trial results with caution, given that their controlled environment (where all patients are instructed in inhaler use) may not be representative of clinical practice in real life. This issue is especially important in the context of different inhaler devices that may have ergonomic designs and functions, as raised by Scichilone et al. in a 2015 review [147]. The key message here is that in day-to-day practice, it may be an efficient strategy to provide patients at higher risk of errors with additional specifically tailored in-depth support with their inhaler use, to ensure they are confident with the correct technique.

Greater attention is clearly needed on the routine review of inhaler technique in the patient population as a whole, as a recent study by Sanchis reported rates of common inhaler errors to be static over a period of several decades [11], and data also show that despite optimally prescribed inhaled therapy, levels of asthma control and COPD disease stability remain poor [18, 145].

In comparison with a previously published systematic review only on DPI inhaler errors, our review encompasses a wider range of device types including the most commonly used inhaler device, the pMDI [14]. Whilst Lavorini et al. included data on critical errors and provided a definition of a critical error, their study focused on the incidence of errors and the possible implications for clinical effectiveness of inhalers [14]. A key strength of our review is that it integrates the link between inhaler errors and disease outcomes and QoL, and provides a systematic overview of how these critical inhaler errors are being assessed and measured.

Direct comparisons and synthesis of the data were challenging due to mixed methodologies (such as observational cross-sectional, or interventional cross-over designs, and designs intended for descriptive or qualitative analysis), different patient populations, and varied endpoints. Yet, despite these differences we observed clear trends in our data. However, due to the vast differences between studies, this review did not examine clinical outcomes by device, but this is an important area for future research.

Furthermore, only a handful of the reviewed studies directly addressed patient outcomes and the economic burden of inhaler errors. Therefore, further research and potential health-economic modelling to understand the relationship between inhaler technique and disease outcomes, and the subsequent impact on societal healthcare systems, is vitally required.

Although the present study shows associations between inhaler errors and patient outcomes through a review of chronic obstructive respiratory diseases as a whole, future research may be able to probe further into the two diseases (asthma and COPD). For example, the generally older age, poor prognosis and comorbidities of COPD patients may influence the degree to which their QoL is increased by improvements in technique and control [148]. The substantially higher prevalence of comorbidities among COPD patients, relative to asthma patients, also likely impacts inhaler technique and patient QoL [148].

With the variety of definitions identified in our review, difficulties arise in determining whether a particular inhaler type is inherently more vulnerable to critical inhaler errors. Consistent use of our proposed definition and categorization by all researchers internationally would transform this area of research and greatly facilitate quantitative and objective comparison between devices, providing a clearer indication of the associated error rates. This would revolutionise everyday clinical practice, where reliable comparisons of error rates would greatly help physicians and aid informed treatment decisions, ensuring the most appropriate device is prescribed for the individual patient with clear implications for personalised patient management. Further research into the association of patient characteristics with error rate could examine “health literacy”, a patient’s insight into their own treatment and health system, and determine if poor knowledge is a risk factor for poor technique [115, 149,150,151].

It is clear that inhaler errors have an effect on disease outcomes, and ultimately patient outcomes and economic burden. This in turn will have an impact on overall disease management and affect not only patients but also the wider healthcare system. These findings are increasingly important given the plethora of devices available to HCPs and patients, and highlight the importance of inhaler mastery in managing and treating asthma and COPD.

There is increasing evidence to suggest that correct inhaler technique (mastery) is fundamental for effective therapy, and that inhaler device type and mastery play important roles in improving adherence, clinical outcomes, quality of life, and use of healthcare resources. Evidence suggests that prescribers should consider patients’ mastery of technique (or lack thereof) and ease of use before changing the dose of inhaled medications, switching to a different inhaler, or adding other treatments to the regimen of patients with poorly controlled asthma. Recent international asthma guidelines highlight the importance of testing and ensuring mastery, alongside checking adherence, before increasing or changing therapy.

Conclusions

In conclusion, the multitude of definitions cited within the literature indicates that there is an urgent need for a consensus in the way in which critical (and non-critical) inhaler errors are defined. We propose defining a critical inhaler error as an action or inaction that in itself would have a definite detrimental impact on the delivery of the drug to the lung, in contrast to a non-critical error which we would define as an action or inaction that in combination with other factors may, or may not, contribute to ineffective delivery of the drug to the lung.

We advocate that there is a real need for an independent international panel of inhalation experts to collectively determine, through evidence and consensus, the definitions of critical and non-critical inhaler errors. If done for each device type, this would demystify the current confusion within the respiratory community.

We also propose that future studies classify individual errors into categories such as inhalation manoeuvre, dose preparation, inhaler handling, device-specific or generic, in order to make comparison and analysis simpler in order to ultimately help healthcare professionals help their patients.

Abbreviations

ACQ :

Asthma Control Questionnaire

ACT:

Asthma Control Test

ATAQ:

Asthma Therapy Assessment Questionnaire

BDI:

Baseline Dyspnoea Index

CAT:

COPD Assessment Test

CI:

Confidence interval

COPD:

Chronic obstructive pulmonary disease

DPI:

Dry-powder inhaler

GINA :

Global Initiative for Asthma

GOLD:

Global Initiative for Chronic Obstructive Lung Disease

GP:

General Practitioner

HCP:

Healthcare provider

ICS:

Inhaled corticosteroid

LABA:

Long-acting beta agonist

MDI:

Metered-dose inhaler

mMRC:

Modified Medical Research Council (questionnaire)

pMDI:

Pressurized metered-dose inhaler

PRISMA:

Preferred Reporting Items for Systematic Reviews and Meta-Analyses

QoL:

quality of life

RCT:

Randomised controlled trial

SGRQ:

St George’s Respiratory Questionnaire

References

  1. Gregory KL, Elliott D, Dunne P. Guide to aerosol delivery devices for physicians, nurses, pharmacists and other health care professionals [https://www.aarc.org/wp-content/uploads/2014/08/aerosol_guide_pro.pdf] Accessed: 10 Nov 2015.

  2. Pritchard JN. Industry guidance for the selection of a delivery system for the development of novel respiratory products. Expert Opin Drug Deliv. 2015;12:1755–65.

    Article  PubMed  CAS  Google Scholar 

  3. Lavorini F, Usmani OS. Correct inhalation technique is critical in achieving good asthma control. Prim Care Respir J. 2013;22:385–6.

    Article  PubMed  Google Scholar 

  4. Wright J, Brocklebank D, Ram F. Inhaler devices for the treatment of asthma and chronic obstructive airways disease (COPD). Qual Saf Health Care. 2002;11:376–82.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  5. Price D, Marshall J, Turner R. Inhaler use in five european countries: analysis of sales data from Q4 2005 to Q4 2011. Value Health. 2012;15:A-PMD92.

    Google Scholar 

  6. Price D, Roche N, Christian Virchow J, Burden A, Ali M, Chisholm A, Lee AJ, Hillyer EV, von Ziegenweidt J. Device type and real-world effectiveness of asthma combination therapy: an observational study. Respir Med. 2011;105:1457–66.

    Article  PubMed  Google Scholar 

  7. Lavorini F, Fontana GA, Usmani OS. New inhaler devices - the good, the bad and the ugly. Respiration. 2014;88:3–15.

    Article  PubMed  Google Scholar 

  8. Haughney J, Price D, Barnes N, Virchow J, Roche N, Chrystyn H. Choosing inhaler devices for people with asthma: current knowledge and outstanding research needs. Respir Med. 2010;3:125–31.

    Google Scholar 

  9. Molimard M, Raherison C, Lignot S, Depont F, Abouelfath A, Moore N. Assessment of handling of inhaler devices in real life: an observational study in 3811 patients in primary care. J Aerosol Med. 2003;16:249–54.

    Article  CAS  PubMed  Google Scholar 

  10. Melani AS, Bonavia M, Cilenti V, Cinti C, Lodi M, Martucci P, Serra M, Scichilone N, Sestini P, Aliani M, Neri M. Inhaler mishandling remains common in real life and is associated with reduced disease control. Respir Med. 2011;105:930–8.

    Article  PubMed  Google Scholar 

  11. Sanchis J, Gich I, Pedersen S. Systematic review of errors in inhaler use: has patient technique improved over time? Chest. 2016;150:394–406.

    Article  PubMed  Google Scholar 

  12. Molimard M, Raherison C, Lignot S, Balestra A, Lamarque S, Chartier A, Droz-Perroteau C, Lassalle R, Moore N, Girodet PO. Chronic obstructive pulmonary disease exacerbation and inhaler device handling: real-life assessment of 2935 patients. Eur Respir J. 2017;49. doi:10.1183/13993003.01794-2016.

  13. Al-Showair RA, Tarsin WY, Assi KH, Pearson SB, Chrystyn H. Can all patients with COPD use the correct inhalation flow with all inhalers and does training help? Respir Med. 2007;101:2395–401.

    Article  PubMed  Google Scholar 

  14. Lavorini F, Magnan A, Christophe Dubus J, Voshaar T, Corbetta L, Broeders M, Dekhuijzen R, Sanchis J, Viejo JL, Barnes P, et al. Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD. Respir Med. 2008;102:593–604.

    Article  PubMed  Google Scholar 

  15. Price D, Bosnic-Anticevich S, Briggs A, Chrystyn H, Rand C, Scheuch G, Bousquet J. Inhaler competence in asthma: common errors, barriers to use and recommended solutions. Respir Med. 2013;107:37–46.

    Article  CAS  PubMed  Google Scholar 

  16. van der Palen J, Klein JJ, Kerkhoff AH, van Herwaarden CL, Seydel ER. Evaluation of the long-term effectiveness of three instruction modes for inhaling medicines. Patient Educ Couns. 1997;32:S87–95.

    Article  CAS  PubMed  Google Scholar 

  17. Price DB, Roman-Rodriguez M, RB MQ, Bosnic-Anticevich S, Carter V, Gruffydd-Jones K, Haughney J, Henrichsen S, Hutton C, Infantino A, et al. Inhaler errors in the CRITIKAL study: type, frequency, and association with asthma outcomes. J Allergy Clin Immunol Pract. 2017;5:1071–1081.e1079.

    Article  PubMed  Google Scholar 

  18. Lewis A, Torvinen S, Dekhuijzen PN, Chrystyn H, Watson AT, Blackney M, Plich A. The economic burden of asthma and chronic obstructive pulmonary disease and the impact of poor inhalation technique with commonly prescribed dry powder inhalers in three European countries. BMC Health Serv Res. 2016;16:251.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  19. Global initiative for chronic obstructive lung disease: pocket guide to COPD diagnosis, management and prevention [http://goldcopd.org/wp-content/uploads/2016/12/wms-GOLD-2017-Pocket-Guide.pdf] Accessed: 26 May 2017.

  20. Global initiative for asthma: pocket guide for asthma management and prevention [http://ginasthma.org/2017-pocket-guide-for-asthma-management-and-prevention/] Accessed: 25 July 2017.

  21. Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gøtzsche PC, Ioannidis JPA, Clarke M, Devereaux PJ, Kleijnen J, Moher D. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. Br Med J. 2009;339:b2700.

  22. IMS Health: IMS MIDAS Q4 MAT 2016, EU5. 2016.

    Google Scholar 

  23. Lavorini F, Corrigan CJ, Barnes PJ, Dekhuijzen PR, Levy ML, Pedersen S, Roche N, Vincken W, Crompton GK. Aerosol drug management improvement team: retail sales of inhalation devices in European countries: so much for a global policy. Respir Med. 2011;105:1099–103.

    Article  CAS  PubMed  Google Scholar 

  24. Basheti IA, Qunaibi E, Bosnic-Anticevich SZ, Armour CL, Khater S, Omar M, Reddel HK. User error with diskus and turbuhaler by asthma patients and pharmacists in Jordan and Australia. Respir Care. 2011;56:1916–23.

    Article  PubMed  Google Scholar 

  25. Batterink J, Dahri K, Aulakh A, Rempel C. Evaluation of the use of inhaled medications by hospital inpatients with chronic obstructive pulmonary disease. Can J Hosp Pharm. 2012;65:111–8.

    PubMed  PubMed Central  Google Scholar 

  26. Deerojanawong J, Na Sakolnakorn VP, Prapphal N, Hanrutakorn C, Sritippayawan S. Evaluation of metered-dose inhaler administration technique among asthmatic children and their caregivers in Thailand. Asian Pac J Allergy Immunol. 2009;27:87–93.

    PubMed  Google Scholar 

  27. Van Der Palen J, Van Der Valk P, Goosens M, Groothuis-Oudshoorn K, Brusse-Keizer M. A randomised cross-over trial investigating the ease of use and preference of two dry powder inhalers in patients with asthma or chronic obstructive pulmonary disease. Expert Opin Drug Deliv. 2013;10:1171–8.

    Article  PubMed  Google Scholar 

  28. Van Der Palen J, Ginko T, Kroker A, Van Der Valk P, Goosens M, Padulles L, Seoane B, Rekeda L, Garcia Gil E. Preference, satisfaction and errors with two dry powder inhalers in patients with COPD. Expert Opin Drug Deliv. 2013;10:1023–31.

    Article  PubMed  Google Scholar 

  29. Voshaar T, Spinola M, Linnane P, Campanini A, Lock D, Lafratta A, Scuri M, Ronca B, Melani AS. Comparing usability of NEXThaler with other inhaled corticosteroid/long-acting beta2-agonist fixed combination dry powder inhalers in asthma patients. J Aerosol Med Pulm Drug Deliv. 2014;27:363–70.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  30. Wieshammer S, Dreyhaupt J. Dry powder inhalers: which factors determine the frequency of handling errors? Respiration. 2008;75:18–25.

    Article  PubMed  Google Scholar 

  31. Capstick T, Clifton I, Morgan J, Silcock J, Blenkinsopp A. Inhaler technique: an unmet need in patients with difficult asthma? Eur Respir J. 2013;42:A-4893.

    Google Scholar 

  32. Nama S, Percival M, Harris M, Nolan-Neylan S, Sivakumaran P, Sriram K, Harland K. Evaluation of inhaler technique and medication adherence in COPD patients. Respirology. 2014;19:A-TP146.

    Google Scholar 

  33. Vanderman AJ, Moss JM, Bailey JC, Melnyk SD, Brown JN. Inhaler misuse in an older adult population. Consult Pharm. 2015;30:92–100.

    Article  PubMed  Google Scholar 

  34. Pothirat C, Chaiwong W, Phetsuk N, Pisalthanapuna S, Chetsadaphan N, Choomuang W. Evaluating inhaler use technique in COPD patients. Int J Chron Obstruct Pulmon Dis. 2015;10:1291–8.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  35. Madkour A, Galal I. Do Egyptian patients use their inhalers correctly? A checklist auditing for inhalation devices usage techniques. Egyptian J Chest Dis Tuberculosis. 2015;64:497–504.

    Article  Google Scholar 

  36. Ozturk C, Aldag Y. Evaluation and importance of different types of inhaler device use in patients with chronic obstructive lung disease (COPD). Respirology. 2015;20(S3):A-471.

  37. Chrystyn H, Price DB, Molimard M, Haughney J, Bosnic-Anticevich S, Lavorini F, Efthimiou J, Shan D, Sims E, Burden A. Comparison of serious inhaler technique errors made by device-naïve patients using three different dry powder inhalers: a randomised, crossover, open-label study. BMC Pulm Med. 2016;16:12.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  38. Coelho ACC, Souza-Machado A, Leite M, Almeida P, Castro L, Cruz CS, Stelmach R, Cruz AA. Use of inhaler devices and asthma control in severe asthma patients at a referral center in the city of Salvador, Brazil. J Bras Pneumol. 2011;37:720–8.

    Article  PubMed  Google Scholar 

  39. Giraud V, Allaert FA, Roche N. Inhaler technique and asthma: Feasability and acceptability of training by pharmacists. Respir Med. 2011;105:1815–22.

    Article  PubMed  Google Scholar 

  40. Hagmolen of ten Have W, van de Berg NJ, Bindels PJ, van Aalderen WM, van der Palen J. Assessment of inhalation technique in children in general practice: increased risk of incorrect performance with new device. J Asthma. 2008;45:67–71.

    Article  PubMed  Google Scholar 

  41. Mehuys E, Boussery K, Adriaens E, van Bortel L, De Bolle L, van Tongelen I, Remon JP, Brusselle G. COPD management in primary care: an observational, community pharmacy-based study. Ann Pharmacother. 2010;44:257–66.

    Article  PubMed  Google Scholar 

  42. Molimard M, Gros VL. Impact of patient-related factors on asthma control. J Asthma. 2008;45:109–13.

    Article  PubMed  Google Scholar 

  43. Rajan S, Gogtay J. Ease-of-use, preference, confidence, and satisfaction with Revolizer, a novel dry powder inhaler, in an Indian population. Lung India. 2014;31:366–74.

    Article  PubMed  PubMed Central  Google Scholar 

  44. Rootmensen G, Van Keimpema AR, Jansen HM, De Haan RJ. Predictors of incorrect inhalation technique in patients with asthma or COPD. Am J Respir Crit Care Med. 2010;181:A-3812.

    Google Scholar 

  45. Schulte M, Osseiran K, Betz R, Wencker M, Brand P, Meyer T, Haidl P. Handling of and preferences for available dry powder inhaler systems by patients with asthma and COPD. J Aerosol Med Pulm Drug Deliv. 2008;21:321–8.

    Article  CAS  PubMed  Google Scholar 

  46. Van Der Palen J, Ginko T, Kroker A, Van Der Valk P, Goosens M, Padulles L, Seoane B, Rekeda L, Gil EG. Comparison of the preference, satisfaction, and critical errors made with Genuair and Handihaler in patients with COPD. Chest. 2012;142:A-717A.

    Article  Google Scholar 

  47. Molimard M. How to achieve good compliance and adherence with inhalation therapy. Curr Med Res Opin. 2005;21:S33–7.

    Article  PubMed  Google Scholar 

  48. Westerik JA, Carter V, Chrystyn H, Burden A, Thompson SL, Ryan D, Gruffydd-Jones K, Haughney J, Roche N, Lavorini F, et al. Characteristics of patients making serious inhaler errors with a dry powder inhaler and association with asthma-related events in a primary care setting. J Asthma. 2016;53:321–9.

    Article  PubMed  PubMed Central  Google Scholar 

  49. Chrystyn H, Bosnic-Anticevich S, Roche N, Molimard M, Haughney J, Lavorini F, Shan D, Sims E, Burden A, Ashton VL. Prevalence of serious post-training inhaler technique errors made by device-naïve patients using three different dry powder inhalers (DPIs). Eur Respir J. 2015;46:A-P3927.

    Google Scholar 

  50. Thomas M, Van der Palen J, Chrystyn H, Sharma R, Imber V, Zhu C-Q, Barnes N. Inhaler errors and preference: a comparison of two multi-dose powder asthma inhalers. Respirology. 2015;20:A-573.

    Article  Google Scholar 

  51. Li H, Chen Y, Zhang Z, Dong X, Zhang G, Zhang H. Handling of diskus dry powder inhaler in Chinese chronic obstructive pulmonary disease patients. J Aerosol Med Pulm Drug Deliv. 2014;27:219–27.

    Article  PubMed  Google Scholar 

  52. Melani AS, Canessa P, Coloretti I, Deangelis G, Detullio R, Del Donno M, Giacobbe R, Scarlato I, Serafini A, Barbato N, et al. Inhaler mishandling is very common in patients with chronic airflow obstruction and long-term home nebuliser use. Respir Med. 2012;106:668–76.

    Article  PubMed  Google Scholar 

  53. Capanoglu M, Dibek Misirlioglu E, Toyran M, Civelek E, Kocabas CN. Evaluation of inhaler technique, adherence to therapy and their effect on disease control among children with asthma using metered dose or dry powder inhalers. J Asthma. 2015;52:838–45.

    Article  PubMed  CAS  Google Scholar 

  54. Pascual S, Feimer J, De Soyza A, Sauleda Roig J, Haughney J, Padulles L, Seoane B, Rekeda L, Ribera A, Chrystyn H. Preference, satisfaction and critical errors with Genuair and Breezhaler inhalers in patients with COPD: a randomised, cross-over, multicentre study. NPJ Prim Care Respir Med. 2015;25:15018.

    Article  PubMed  PubMed Central  Google Scholar 

  55. Bryant L, Bang C, Chew C, Hee Baik S, Wiseman D. Adequacy of inhaler technique used by people with asthma or chronic obstructive pulmonary disease. JJ Prim Health Care. 2013;5:191–8.

    Google Scholar 

  56. Dalcin PTR, Grutcki DM, Laporte PP, de Lima PB, Menegotto SM, Pereira RP. Factors related to the incorrect use of inhalers by asthma patients. J Bras Pneumol. 2014;40:13–20.

    Article  PubMed Central  Google Scholar 

  57. Giraud V, Allaert FA, Magnan A. A prospective observational study of patient training in use of the autohaler inhaler device: the sirocco study. Eur Rev Med Pharmacol Sci. 2011;15:563–70.

    CAS  PubMed  Google Scholar 

  58. Harnett CM, Hunt EB, Bowen BR, O'Connell OJ, Edgeworth DM, Mitchell P, Eustace JA, Henry MT, Kennedy MP, Plant BJ, Murphy DM. A study to assess inhaler technique and its potential impact on asthma control in patients attending an asthma clinic. J Asthma. 2014;51:440–5.

    Article  CAS  PubMed  Google Scholar 

  59. Loh LC, Teng CL, Teh PN, Koh CN, Vijayasingham P, Thayaparan T. Metered-dose inhaler technique in asthmatic patients - a revisit of the Malaysian scene. Med J Malaysia. 2004;59:335–41.

    CAS  PubMed  Google Scholar 

  60. Chorao P, Pereira AM, Fonseca JA. Inhaler devices in asthma and COPD - an assessment of inhaler technique and patient preferences. Respir Med. 2014;108:968–75.

    Article  PubMed  Google Scholar 

  61. Hammerlein A, Muller U, Schulz M. Pharmacist-led intervention study to improve inhalation technique in asthma and COPD patients. J Eval Clin Pract. 2011;17:61–70.

    Article  PubMed  Google Scholar 

  62. Al-Hassan MI. Assessment of inhaler technique in patients attending a chest hospital in Riyadh City. Int J Pharmacol. 2009;5:232–5.

    Article  Google Scholar 

  63. Komase Y, Asako A, Kobayashi A, Sharma R. Ease-of-use preference for the ELLIPTA dry powder inhaler over a commonly used single-dose capsule dry powder inhaler by inhalation device-naive Japanese volunteers aged 40 years or older. Int J COPD. 2014;9:1365–75.

    Article  Google Scholar 

  64. Ozturk C, Kaya A, Bilgin C, Yucesoy L, Ikidag B, Demirel M, Baslilar S, Saylan B, Senol T, Aganoglu S, et al. Evaluation of inhaler technique and patient satisfaction with fixed-combination budesonide/formoterol dry-powder inhaler in chronic obstructive pulmonary disease (COPD): data on real-life clinical practice in Turkey. Tuberk Toraks. 2012;60:301–13.

    Article  PubMed  Google Scholar 

  65. Nolan-Neylan S, Harris M, Harland K, Sriram K. Evaluation of inhaler technique in hospitalised COPD patients. Respirology. 2015;20:A-P002.

    Google Scholar 

  66. Lee SM, Chang YS, Kim CW, Kim TB, Kim SH, Kwon YE, Lee JM, Lee SK, Jeong JW, Park JW, et al. Skills in handling Turbuhaler, Diskus, and pressurized metered-dose inhaler in Korean asthmatic patients. Allergy Asthma Immunol Res. 2010;3:46–52.

    Article  PubMed  PubMed Central  Google Scholar 

  67. Al-Jahdali H, Ahmed A, Al-Harbi A, Khan M, Baharoon S, Bin Salih S, Halwani R, Al-Muhsen S. Improper inhaler technique is associated with poor asthma control and frequent emergency department visits. Allergy Asthma Clin Immunol. 2013;9:8.

    Article  PubMed  PubMed Central  Google Scholar 

  68. Maricoto T, Rodrigues LV, Teixeira G, Valente C, Andrade L, Saraiva A. Assessment of inhalation technique in clinical and functional control of asthma and chronic obstructive pulmonary disease. Acta Med Port. 2015;28:702–7.

    Article  PubMed  Google Scholar 

  69. Manriquez P, Acuna AM, Munoz L, Reyes A. Study of inhaler technique in asthma patients: differences between pediatric and adult patients. J Bras Pneumol. 2015;41:405–9.

    Article  PubMed  PubMed Central  Google Scholar 

  70. Sriram KB, Percival M. Suboptimal inhaler medication adherence and incorrect technique are common among chronic obstructive pulmonary disease patients. Chron Respir Dis. 2015;13:13–22.

    Article  PubMed  PubMed Central  Google Scholar 

  71. Buset EMN, Liaaen ED, Roth K, Blix HS. Inhalation technique in hospitalized asthma and COPD patients: should patients be regularly assessed before discharge? Int J Clin Pharm. 2015;37:A-16.

    Google Scholar 

  72. Cayo-Quiñe A, Martínez-Vargas V, Bustamante-Voysest R, Piscoya A, Alberca Y: Incorrect use of metered-dose inhalers in adult patients at a hospital in Callao, Peru, 2014: cross-sectional study. Medwave 2014, 15:e6163-e6163.

  73. Sangita P, Gharti KP, Laxman B. Assessment of inhalation techniques in COPD patients using metered-dose inhaler and Rotahaler at a tertiary care hospital in Nepal. Int Res J Pharm. 2015;6:288–93.

    Article  Google Scholar 

  74. Villamil-Osorio M, Medina L, Pernett L, Restrepo SM, Nino G, Rodriguez-Martinez C. Assessment of inhalation technique and predictors of poor inhalation technique in a population of asthmatic children. J Aerosol Med Pulm Drug Deliv. 2015;191:A-3370.

    Google Scholar 

  75. Udwadia ZZ, Kathar S, Shah HD, Pandey K, Rastogi S, Mullerpattan J. Who will teach the teachers: an analysis of the inhaler technique of Indian patients and health care providers. Am J Res Crit Care Med. 2013;187:A5026.

  76. Turan P, Itil O, Turan M. Factors effecting inhaler technique in COPD. Am J Res Crit Care Med. 2014;189:A-6000.

  77. Wu H, Thomas L, Bime C. An assessment of inhaler technique among patients with chronic obstructive airway diseases in a health professional shortage area. Am Philos Soc. 2013;187:A4208.

  78. Baddar S, Jayakrishnan B, Al-Rawas OA. Asthma control: importance of compliance and inhaler technique assessments. J Asthma. 2014;51:429–34.

    Article  PubMed  Google Scholar 

  79. Sadowski C, Banh H, Cor K, Cave A. Inhaler device technique in community-dwelling older adults. Canadian Journal of. Hosp Pharm. 2013;66(4):269.

    Google Scholar 

  80. Camilleri K, Balzan M, Bardon MP, Schembri E, Sullivan M, Mifsud S, Muscat D, Asciaq R, Montefort S. Predictors of good inhaler technique in asthma and COPD. Eur Respir J. 2015;46:A-P3928.

    Google Scholar 

  81. Ganguly A, Das A, Roy A, Adhikari A, Banerjee J, Sen S. Study of proper use of inhalational devices by bronchial asthma or copd patients attending a tertiary care hospital. J Clin Diagn Res. 2014;8:HC04–7.

    PubMed  PubMed Central  Google Scholar 

  82. Khassawneh BY, Al-Ali MK, Alzoubi KH, Batarseh MZ, Al-Safi SA, Sharara AM, Alnasr HM. Handling of inhaler devices in actual pulmonary practice: metered-dose inhaler versus dry powder inhalers. Respir Care. 2008;53:324–8.

    PubMed  Google Scholar 

  83. Barthwal MS, Katoch CDS, Marwah V. Impact of optimal asthma education programme on asthma morbidity, inhalation technique and asthma knowledge. J Assoc Physicians India. 2009;57:574–9.

    CAS  PubMed  Google Scholar 

  84. Basheti IA, Armour CL, Bosnic-Anticevich SZ, Reddel HK. Evaluation of a novel educational strategy, including inhaler-based reminder labels, to improve asthma inhaler technique. Patient Educ Couns. 2008;72:26–33.

    Article  PubMed  Google Scholar 

  85. Burkhart PV, Rayens MK, Bowman RK. An evaluation of children's metered-dose inhaler technique for asthma medications. Nurs Clin N Am. 2005;40:167–82.

    Article  Google Scholar 

  86. Carpenter DM, Lee C, Blalock SJ, Weaver M, Reuland D, Coyne-Beasley T, Mooneyham R, Loughlin C, Geryk LL, Sleath BL. Using videos to teach children inhaler technique: a pilot randomized controlled trial. J Asthma. 2015;52:81–7.

    Article  PubMed  Google Scholar 

  87. Garcia-Cardenas V, Sabater-Hernandez D, Kenny P, Martinez-Martinez F, Faus MJ, Benrimoj SI. Effect of a pharmacist intervention on asthma control. A cluster randomised trial. Respir Med. 2013;107:1346–55.

    Article  PubMed  Google Scholar 

  88. Goris S, Tasci S, Elmali F. The effects of training on inhaler technique and quality of life in patients with COPD. J Aerosol Med Pulm Drug Deliv. 2013;26:336–44.

    Article  PubMed  CAS  Google Scholar 

  89. Hesselink AE, Penninx BWJH, Van Der Windt DAWM, Van Duin BJ, De Vries P, Twisk JWR, Bouter LM, Van Eijk JTM. Effectiveness of an education programme by a general practice assistant for asthma and COPD patients: results from a randomised controlled trial. Patient Educ Couns. 2004;55:121–8.

    Article  PubMed  Google Scholar 

  90. Levy ML, Hardwell A, McKnight E, Holmes J. Asthma patients' inability to use a pressurised metered-dose inhaler (pMDI) correctly correlates with poor asthma control as defined by the global initiative for asthma (GINA) strategy: a retrospective analysis. Prim Care Res J. 2013;22:406–11.

    Google Scholar 

  91. Maazuddin M, Hazari MAH, Hasan A, Javeedullah M, Nasir Mohiuddin M, Baig MMA. Training in the use of inhalation devices and respiratory improvement in asthma and COPD patients: a before-after experimental study. Pharmanest. 2014;5:2314–20.

    Google Scholar 

  92. Minai BA, Martin JE, Cohn RC. Results of a physician and respiratory therapist collaborative effort to improve long-term metered-dose inhaler technique in a pediatric asthma clinic. Respir Care. 2004;49:600–5.

    PubMed  Google Scholar 

  93. Van Der Palen J, Eijsvogel MM, Kuipers BF, Schipper M, Vermue NA. Comparison of the Diskus inhaler and the Handihaler regarding preference and ease of use. J Aerosol Med. 2007;20:38–44.

    Article  PubMed  Google Scholar 

  94. Yildiz F, Erbagci A, Demirel YS, Akcali SD, Ekici A, Dursunoglu N, Ediger D, Erdinc M, Cemri SC, Kalyoncu AF, et al. Importance of inhaler device use status in the control of asthma in adults: the asthma inhaler treatment study. Respir Care. 2014;59:223–30.

    Article  PubMed  Google Scholar 

  95. Elgendy MO, Abdelrahim ME, Eldin RS. Potential benefit of repeated MDI inhalation technique counselling for patients with asthma. Eur J Hosp Pharm. 2015;22:318–22.

    Article  Google Scholar 

  96. Grover C, Goel N, Armour C, Van Asperen P, Gaur S, Moles R, Saini B. Medication education program for Indian children with asthma: a feasibility study. Niger J Clin Pract. 2016;19:76–84.

    Article  CAS  PubMed  Google Scholar 

  97. Kuna P, Kupryś-Lipińska I, Dębowski T. Control of asthma in adults treated with beclomethasone and formoterol in extrafine particle formulation in a real-life setting in Poland: the CASPER noninterventional, observational trial. Pol Arch Med Wewn. 2015;125:731–40.

    PubMed  Google Scholar 

  98. Plaza V, Peiró M, Torrejón M, Fletcher M, López-Viña A, Ignacio JM, Quintano JA, Bardagí S, Gich I. A repeated short educational intervention improves asthma control and quality of life. Eur Respir J. 2015;46:1298–307.

    Article  CAS  PubMed  Google Scholar 

  99. Bell D, Mansfield L, Lomax M, Dissanayake S. Patient handling study of fluticasone propionate/formoterol fumarate pressurized metered-dose inhaler. Respirology. 2014;19:A-O016.

    Google Scholar 

  100. Kuprys-Lipinska I, Wiacek K, Przyrowski R, Kuna P. The educational program on the inhalation technique in a group of patients with asthma and COPD using Aerolizer - the effectiveness and the patients' satisfaction. J Allergy Clin Immunol. 2011;1:A-443.

    Google Scholar 

  101. Lin HL, Ng SP, Chen CH, Chien SY. Pharmacist-led educational interventions to improve inhalation technique in pediatric asthma patients. Pharmacoepidemiol Drug Saf. 2014;23:A-P414.

    Google Scholar 

  102. Shetty F, Gupta R. Improved MDI inhaler technique observed in adult asthma patients with web based education. Eur Respir J. 2013;42:A-4959.

    Google Scholar 

  103. Takemura M, Mitsui K, Ido M, Koyama M, Matsumoto M, Inoue D, Takamatsu K, Itotani R, Ishitoko M, Suzuki S. Clinical impact of a program to educate community pharmacists in providing proper inhalation technique for asthma patients. Eur Respir J. 2011;38:2845.

  104. Maricoto T, Madanelo S, Rodrigues L, Teixeira G, Valente C, Andrade L, Saraiva A. Inhalation technique education and its impact in asthma and COPD. Eur Respir J. 2015;46:A-P5019.

    Google Scholar 

  105. Fernandes L, Mesquita A. Improving asthma control with therapeutic education intervention. Eur Respir J. 2011;38:A-P4997.

    Google Scholar 

  106. Barnestein-Fonseca P, Leiva-Fernández F, Vazquez-Alarcon R, Aguiar-Leiva V, Lobnig-Becerra M, Leiva-Fernández J. Can we improve the inhalation techniques in patients with COPD? Tiepoc study. Value Health. 2015;7:A-PRS10.

    Google Scholar 

  107. Van Der Valk P, Goosens M, Groothuis-Oudshoorn K, Brusse-Keizer M, van der Palen J. Comparing the ease of use, preference and satisfaction of Accuhaler/Diskus and Elpenhaler in patients with asthma or chronic obstructive pulmonary disease. Am J Respir Crit Care Med. 2013;187:A2336.

  108. Prieto-Centurion V, Bracken NE, Jaffe HA, Hauser J, Norwick L, Krishnan JA, Zaidi F. Reducing avoidable readmissions following COPD exacerbations among US veterans: the importance of teaching appropriate use of respiratory inhalers. Am J Respir Crit Care Med. 2015;191:A6177.

  109. Wiacek K, Kuna P, Kuprys-Lipinska I. The clinical effectiveness of the improvement of the inhalation technique in patients using aerolizer-2nd phase of the educational-observational program. American J Res Crit Care Med. 2012:185, A-5625.

  110. Lee S-Y, Park H-W, Song W-J, Cho S-H. A multifaceted approach to reduce acute exacerbations in elderly asthmatics. Chest. 2015;148:A-11A.

    Article  Google Scholar 

  111. Ammari W, Al-Hyari N, Obeidat N, Khater M, Sabouba A, Sanders M. Improving paediatrics' pressurised metered dose inhaler technique and asthma control: inhaler verbal counselling vs. Trainhaler. Thorax. 2015;70:A-P100.

    Article  Google Scholar 

  112. Ronk J, Alarcon L, Loughlin C. Implementing standardized metered-dose-inhaler (MDI) spacer technique checklist for pediatric asthma patients across University of North Carolina (UNC) Children's hospital. Am J Respir Crit Care Med. 2012;185:A-3359.

    Google Scholar 

  113. Al-Doghim I. Evaluation of inhalation technique of metered dose inhaler (MDI) and dry powder inhaler-Turbuhaler (DPI) among pediatric patients with asthma. J Appl Sci. 2007;9:53–66.

    Google Scholar 

  114. Khan G, Badri P, Parbati T, Anita D, Atul A, Deepak P, Dipendra R, Himal B, Kabita G, Nirmala K. Intervention on inhalation technique of Rotahaler in patients with chronic obstructive pulmonary disease and asthma. Asian J Pharm Sci. 2016;11:81–2.

    Article  Google Scholar 

  115. Alsomali H, Vines DL, Stein BD, EA B: Evaluating the health literacy and effectiveness of written dry powder inhaler instructions in patients diagnosed with chronic obstructive pulmonary disease. Am Assoc Res Care Open Forum 2015, 60:A-2303288.

  116. Benjamin JA, Williams R, Bruce K, Jones O, Philips L. A 2 year programme to improve inhaler technique for adult patients with asthma and chronic obstructive pulmonary disease in a welsh university health board. Eur Respir J. 2015;46:A-P3929.

    Google Scholar 

  117. Sulaiman I, MacHale E, Seheult J, D'Arcy S, Rapcan V, Mokoka M, Cushen B, Killane I, Franciosi A, Sahadevan A. Feedback on adherence and inhaler technique using the Inca device: a randomised control trial in severe asthma. Am J Respir Crit Care Med. 2016;193:A-1714.

    Google Scholar 

  118. Thomas M, Van Der Palen J, Chrystyn H, Zhu C, Ghatta S, Svedsater H. Time to achieve correct inhaler use and inhaler preference: a comparison of Ellipta® with three inhaler devices in patients with asthma. Am J Respir Crit Care Med. 2016;193:A-1739.

    Google Scholar 

  119. Van Der Palen J, Thomas M, Chrystyn H, Sharma R, Imber V, Zhu C-Q, Svedsater H. Training and time to achieve correct inhaler use: a comparison between inhalers in patients with COPD. In: AJRCCM conference. San Francisco, CA, US: American Thoracic Society; 2016. p. A-6812.

    Google Scholar 

  120. Juniper EF, O'Byrne PM, Guyatt GH, Ferrie PJ, King DR. Development and validation of a questionnaire to measure asthma control. Eur Respir J. 1999;14:902–7.

    Article  CAS  PubMed  Google Scholar 

  121. Nathan RA, Sorkness CA, Kosinski M, Schatz M, Li JT, Marcus P, Murray JJ, Pendergraft TB. Development of the asthma control test: a survey for assessing asthma control. J Allergy Clin Immunol. 2004;113:59–65.

    Article  PubMed  Google Scholar 

  122. Azevedo P, Correia de Sousa J, Bousquet J, Bugalho-Almeida A, Del Giacco SR, Demoly P, Haahtela T, Jacinto T, Garcia-Larsen V, van der Molen T, et al. Control of allergic rhinitis and asthma test (CARAT): dissemination and applications in primary care. Prim Care Res J. 2013;22:112–6.

    Google Scholar 

  123. Skinner EA, Diette GB, Algatt-Bergstrom PJ, Nguyen TT, Clark RD, Markson LE, AW W. The asthma therapy assessment questionnaire (ATAQ) for children and adolescents. Dis Manag. 2004;7:305–13.

    Article  PubMed  Google Scholar 

  124. Murphy KR, Zeiger RS, Kosinski M, Chipps B, Mellon M, Schatz M, Lampl K, Hanlon JT, Ramachandran S. Test for respiratory and asthma control in kids (TRACK): a caregiver-completed questionnaire for preschool-aged children. J Allergy Clin Immunol. 2009;123:833–9. e839

    Article  PubMed  Google Scholar 

  125. Groot EP, Kreggemeijer WJ, Brand PL. Getting the basics right resolves most cases of uncontrolled and problematic asthma. Acta Paediatr. 2015;104:916–21.

    Article  PubMed  Google Scholar 

  126. Zaidi S, Williams J, Monaghan T, Burhan H, Main N. Inhaler Technique: Does Poor Technique Mean More Admissions? Am J Respir Crit Care Med. 2012;185:A-3333.

    Google Scholar 

  127. Roggeri A, Micheletto C, Boarino S, Inzillo V, Roggeri DP. Potential economic impact of inhalation errors due to device switch in patients with chronic obstructive pulmonary disease and asthma. Value Health. 2015;18:A-PMD147.

    Google Scholar 

  128. Roggeri A, Micheletto C, Roggeri DP. Inhalation errors due to device switch in patients with chronic obstructive pulmonary disease and asthma: critical health and economic issues. Int J Chron Obstruct Pulmon Dis. 2016;11:597–602.

    Article  PubMed  PubMed Central  Google Scholar 

  129. Bijos P, Kaczynski J, Torvinen S, Lenarczyk E, Wrona W, Plich A, Lewis A, Blackney M. Clinical and economic burden of asthma and chronic obstructive pulmonary disease (COPD) in Poland: estimated impact of poor inhalation technique with inhaled corticosteroid and long-acting beta agonist fixed-dose combinations. Value Health. 2015;18:A-PRS34.

    Article  Google Scholar 

  130. Torvinen S, Nicolai J, Pulimeno S, di Nola L, Bruno G, Colombo G, Di Matteo S, Valentino M, Lewis A, Blackney M. The budget impact of Duoresp® Spiromax® compared with commonly prescribed dry powder inhalers for the management of asthma and chronic obstructive pulmonary disease in Italy: estimated impact of inhalation technique. Value Health. 2015;18:A-PRS16.

    Google Scholar 

  131. Lewis A, Blackney M, Torvinen S, Plich A. Clinical and economic burden of asthma and chronic obstructive pulmonary disease in the UK: impact of critical inhaler errors with inhaled corticosteroid + long-acting beta agonist fixed-dose combinations. Value Health. 2014;17:A-PRS30.

    Article  Google Scholar 

  132. Lewis A, Blackney M, Garcia BL, Sánchez-de la Rosa R, Torvinen S, Plich A. The potential for improved inhalation technique with Duoresp® Spiromax®(budesonide+formoterol fumarate dihydrate) compared with commonly prescribed dry powder inhalers for the management of asthma and chronic obstructive pulmonary disease in Spain: estimated impact on number and cost of unscheduled healthcare events. Value Health. 2015;18:A-PMD37.

    Google Scholar 

  133. Lewis A, Blackney M, Torvinen S, Lindqvist F, Safioti G, Grundstrom J, Polyzoi M, Plich A. The potential societal cost benefits of improved inhalation technique with Duoresp Spiromax (budesonide + formoterol fumarate dihydrate) compared with Symbicort Turbuhaler for the management of asthma and chronic obstructive pulmonary disease in sweden. Value Health. 2014;17:A-PRS62.

    Article  Google Scholar 

  134. Lewis A, Blackney M, Torvinen S, Holmes J, Osborne M, Dale J, Chandler S, Plich A. The budget impact of Duoresp Spiromax (budesonide + formoterol fumarate dihydrate) compared with Symbicort Turbohaler for the management of asthma and chronic obstructive pulmonary disease in the United Kingdom: impact on health care costs and inhalation technique. Value Health. 2014;17:A-PRS19.

    Article  Google Scholar 

  135. Estrada J, Restrepo A, Serna J, Herrera R, Arrieta J, Segura A. Impact of a pharmacotherapeutic follow-up program on the cost-month-patient, stratified by risk-pharmacological type. Value Health. 2015;18:A-PRS14.

    Google Scholar 

  136. Basheti I, Bosnic-Anticevich S, Armour C, Reddel H. Checklists for powder inhaler technique: a review and recommendations. Respir Care. 2014;59:1140–54.

    Article  PubMed  Google Scholar 

  137. Basheti IA, Reddel HK, Armour CL, Bosnic-Anticevich SZ. Improved asthma outcomes with a simple inhaler technique intervention by community pharmacists. J Allergy Clin Immunol. 2007;119:1537–8.

    Article  PubMed  Google Scholar 

  138. Sulaiman I, Seheult J, Sadasivuni N, Cushen B, Mokoka M, Costello R. Inhaler technique errors have an impact on drug delivery. Am J Respir Crit Care Med. 2016;193:A-1715.

    Google Scholar 

  139. Molimard M, Raherison C, Lignot S, Balestra A, Lamarque S, Chartier A, Droz-Perroteau C, Lassalle R, Moore N, Girodet P-O. Chronic obstructive pulmonary disease exacerbation and inhaler device handling: real-life assessment of 2935 patients. Eur Respir J. 2016;49

  140. Price DB, Roman-Rodriguez M, McQueen RB, Bosnic-Anticevich S, Carter V, Gruffydd-Jones K, Haughney J, Henrichsen S, Hutton C, Infantino A, et al. Inhaler errors in the CRITIKAL study: type, frequency, and association with asthma outcomes. J Allergy Clin Immunol Pract. 2017;5:1071–1081.e1079.

    Article  PubMed  Google Scholar 

  141. Williams SA, Wagner S, Kannan H, Bolge SC. The association between asthma control and health care utilization, work productivity loss and health-related quality of life. J Occup Environ Med. 2009;51:780–5.

    Article  PubMed  Google Scholar 

  142. Vervloet D, Williams A, Lloyd A, Clark T. Costs of managing asthma as defined by a derived asthma control TestTM score in seven European countries. Eur Respir Rev. 2006;15:17–23.

    Article  Google Scholar 

  143. Szende A, Svensson K, Ståhl E, Meszaros A, Berta GY. Psychometric and utility-based measures of health status of asthmatic patients with different disease control level. PharmacoEconomics. 2004;22:537–47.

    Article  PubMed  Google Scholar 

  144. Doz M, Chouaid C, Com-Ruelle L, Calvo E, Brosa M, Robert J, Decuypere L, Pribil C, Huerta A, Detournay B. The association between asthma control, health care costs, and quality of life in France and Spain. BMC Pulm Med. 2013;13:15.

    Article  PubMed  PubMed Central  Google Scholar 

  145. Demoly P, Annunziata K, Gubba E, Adamek L. Repeated cross-sectional survey of patient-reported asthma control in Europe in the past 5 years. Eur Respir Rev. 2012;21:66–74.

    Article  CAS  PubMed  Google Scholar 

  146. Jha A, Heron L, Marshall J, Dunlop W. Device handling errors and the impact on quality of life and health care resource use in asthmatic patients. Value Health. 2014;17:A-PRS64.

    Google Scholar 

  147. Scichilone N, Benfante A, Bocchino M, Braido F, Paggiaro P, Papi A, Santus P, Sanduzzi A. Which factors affect the choice of the inhaler in chronic obstructive respiratory diseases? Pulm Pharmacol Ther. 2015;31:63–7.

    Article  CAS  PubMed  Google Scholar 

  148. Lavorini F, Mannini C, Chellini E, Fontana GA. Optimising inhaled pharmacotherapy for elderly patients with chronic obstructive pulmonary disease: the importance of delivery devices. Drugs Aging. 2016;33:461–73.

    Article  CAS  PubMed  Google Scholar 

  149. Perez L, Morales K, Huang J, Ndicu G, Han X, Klusaritz H, Localio A, Apter AJ. Aspects of asthma self-management: inhaler technique, ability to access (navigate) health care, and inhaled steroid knowledge are correlated. Am J Res Crit Care Med. 2016;193:A6426.

  150. Kiser K, Jonas D, Warner Z, Scanlon K, Shilliday BB, DeWalt DA. A randomized controlled trial of a literacy-sensitive self-management intervention for chronic obstructive pulmonary disease patients. The. J Gen Intern Med. 2012;27:190–5.

    Article  PubMed  Google Scholar 

  151. Paasche-Orlow MK, Riekert KA, Bilderback A, Chanmugam A, Hill P, Rand CS, Brancati FL, Krishnan JA. Tailored education may reduce health literacy disparities in asthma self-management. Am J Respir Crit Care Med. 2005;172:980–6.

    Article  PubMed  PubMed Central  Google Scholar 

  152. Al Zabadi H, El Sharif N. Factors associated with frequent emergency room attendance by asthma patients in Palestine. Int J Tuberc Lung Dis. 2007;11:920–7.

    CAS  PubMed  Google Scholar 

  153. Azouz W, Chetcuti P, Hosker H, Saralaya D, Chrystyn H. Objective measurement of inhalation profiles in patients using metered dose inhalers (MDIs). Eur Respir J. 2011;38:A-838.

    Google Scholar 

  154. Baddar S, Al-Rawas O. What is missing in the asthma control test? The relationship between compliance, inhaler technique and level of control. Eur Respir J. 2012;40:A-P513.

    Article  Google Scholar 

  155. Bilal M, Ahmed A, Shah AR, Mirza HA, Anwar AK, Zaidi SBH. Prevalence of the correct technique of using an inhaler among asthmatic patients reporting in tertiary care hospitals of Rawalpindi, Pakistan. J Allergy Clin Immunol. 2012;1:A-159.

    Google Scholar 

  156. Caliskaner Z, Ozturk C, Pekcan S, Yilmaz O, Ozturk S, Ceylan E, Can C, Sener O, Turay U, Ersoy R. The "extreme" errors in inhaler device use: data from the INTEDA-1 study. In: Allergy; 2011. p. 369–70.

    Google Scholar 

  157. Chrystyn H, Pascual S, Feimer J, De Soyza A, Sauleda Roig J, Haughney J, Padulles L, Seoane B, Rekeda L, Ribera A. Preference, satisfaction and critical errors with Genuair and Breezhaler in patients with COPD. Eur Respir J. 2014;44:A-P928.

    Google Scholar 

  158. Deering B, MacCormack N, Kerrigan K, D'Arcy S, Costello RW. Adherence to inhalers after discharge from hospital following an exacerbation of COPD. Ir J Med Sci. 2013;182:S458.

    Google Scholar 

  159. Hass C, Engdahl K, Albert W, Setyawan J, Mateo N. Patient preferences and perceived ease of use in inhaler features: Genuair vs other inhalers. Chest. 2010;138:A-484.

    Article  Google Scholar 

  160. Herscher M, Ray M, Busse PJ, Wolf MS, Wisnivesky JP, Federman A. Characteristics and outcomes of older adults with early versus late onset asthma. Am J Respir Crit Care Med. 2014;189:A-1359.

    Article  CAS  Google Scholar 

  161. Leiva-Fernandez F, Leiva-Fernandez J, Porcel-Martin C, Prados-Torres D, Garcia-Ruiz AJ, Barnestein-Fonseca P. How do patients with chronic obstructive pulmonary disease (COPD) use their inhalers? Common mistakes. Tecepoc study. Value Health. 2013;16:A-PRS45.

    Google Scholar 

  162. Mazankova D, Mendelova I, Saloun J. Identification of error rate in using inhalation devices by asthmatic patients. Int J Clin Pharm. 2013;35(6):1279–80.

    Google Scholar 

  163. Muhammad I, Haque AS, Muhammad N, Khan JA. Real life perspective in outpatient asthma treatment at a tertiary care center of Pakistan. Respirology. 2009;14:A-PD 10-09.

    Google Scholar 

  164. Santos JC, Silveira BF, Rizzatti F. Knowledge of and technique for using inhalation devices among asthma and COPD patients. Am J Res Crit Care Med. 2014;A-4656

  165. Souza M, Meneghini A, Ferraz E, Vianna E, Borges M. Knowledge of and technique for using inhalation devices among asthma patients and COPD patients. J Bras Pneumol. 2009;35:824–31.

    Article  PubMed  Google Scholar 

  166. Tarsin W, Alshamli I, Soussi M. Preference of the inhaler device and assessment of the technique among the asthmatic and COPD patients. Eur Respir J. 2011;38:A-3981.

    Google Scholar 

  167. Williams J, Mault S, Garner N, Burhan H, Zaidi S. Breaking down bad inhaler technique: device specific advice. Am J Respir Crit Care Med. 2012;185:A-3332.

    Google Scholar 

Download references

Acknowledgements

We would like to thank Alison Saunders, Iván Viejo Viejo and Rebecca Forster for their support in quality checking and co-ordinating this manuscript and Robin Wyn for editorial assistance.

Funding

Funding was provided by Mundipharma International Ltd. to Adelphi Values Ltd. to support this research and the writing of the manuscript. No financial payment was provided to the individual authors of the review.

Availability of data and materials

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

Trademark

® DISKHALER, DISKUS and ROTAHALER are registered trademarks of Glaxo Group Limited.

® ACCUHALER and EVOHALER are registered trademarks (in the European Union) of Glaxo Group Limited.

® REVOLIZER is a registered trade mark (in the United States) of Cipla Limited.

® AUTOHALER is a registered trade mark of 3 M Company.

® STARHALER is a registered trade mark (in India) of Sun Pharma Laboratories Limited.

® TURBUHALER is a registered trade mark (in the European Union) of AstraZeneca AB.

® HANDIHALER and HandiHaler are registered trademarks of Boehringer Ingelheim Pharma GmbH & Co. KG.

® AEROLIZER is a registered trade mark of Novartis AG.

® GENUAIR is a registered trade mark of AstraZeneca AB.

® BREEZHALER is a registered trade mark (in the European Union) of Novartis AG.

® ELPENHALER is a registered trade mark of Elpen Pharmaceutical Co. Inc.

® CYCLOHALER is a registered trade mark (in the European Union) of Pharmachemie B.V.

® EASI-BREATHE is a registered trade mark (in the European Union) of Norton Healthcare Limited.

® PULVINAL is a registered trade mark (in the European Union) of Chiesi Farmaceutici S.p.A.

® PULMOJET is a registered trade mark (in the European Union) of Sanofi S.A.

Author information

Authors and Affiliations

Authors

Contributions

All authors have contributed equally to the analysis, review, writing and finalisation of this manuscript. All authors have read and approved the final manuscript.

Corresponding author

Correspondence to Omar Sharif Usmani.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

In the last 5 years, Omar S. Usmani and/or his department received research grants, unrestricted educational grants, and/or fees for lectures and advisory board meetings from Aerocrine, Astra Zeneca, Boehringer Ingelheim, Chiesi, Cipla, Edmond Pharma, GlaxoSmithKline, Napp, Mundipharma International, Prosonix, Sandoz, Takeda, Zentiva.

In the last 5 years, Federico Lavorini received fees for lectures and advisory board meetings from Astra Zeneca, Boehringer Ingelheim, Chiesi, Cipla, Menarini International, TEVA, Zentiva.

In the last 3 years, Richard Dekhuijzen and/or his department received research grants, unrestricted educational grants, and/or fees for lectures and advisory board meetings from AstraZeneca, Boehringer Ingelheim, Chiesi, GSK, Mundipharma International, Novartis, Takeda and Teva.

William Dunlop and Jonathan Marshall are employees of Mundipharma International Ltd., United Kingdom.

Emily Farrington and Louise Heron are employees of Adelphi Values Ltd., UK. Adelphi Values Ltd. received funding from Mundipharma International Ltd. to support this research.

The authors do not report any conflict of interest with regards to the contents of this study other than those stated.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Additional file

Additional file 1:

One supplementary file is associated with this manuscript: “Online Resource – Critical handling errors in asthma and COPD: A systematic review of impact on health outcomes”. This contains: search strategies and details of the analysis conducted within this literature review (Table S1); a breakdown of grouped critical errors described in the literature for different inhaler device types (Table S2); summaries of pre-existing known publications that show associations between poor disease control, economic burden and poor QoL (Table S3); definitions of a ‘critical’ error provided by studies captured within the literature review (Table S4). This file is named: “Critical handling errors data supplement update v8_0”. (DOCX 588 kb)

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Usmani, O.S., Lavorini, F., Marshall, J. et al. Critical inhaler errors in asthma and COPD: a systematic review of impact on health outcomes. Respir Res 19, 10 (2018). https://doi.org/10.1186/s12931-017-0710-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12931-017-0710-y

Keywords