Skip to main content

Table 3 ROC curve analyses

From: Evaluation of computed tomography in the diagnosis of ultrasound-proven diaphragm dysfunction

Group

Measurement

Side

AUC

95%CI

Threshold

Accuracy

Se (%)

Spe (%)

PPV (%)

NPV (%)

Paralysis

L1 (mm)

R

0.93

84–100

4.5

0.87

87

87

95

70

Celiac (mm)

R

0.84

70–98

3.0

0.75

71

87

94

50

L1 (mm)

L

0.99

95–100

3.8

0.93

92

94

96

89

Celiac (mm)

L

0.97

93–100

2.6

0.95

100

88

92

100

Weakness

L1 (mm)

R

0.67

43–92

9.4

0.81

57

87

57

87

Celiac (mm)

R

0.73

49–96

4.9

0.84

71

84

62

91

L1 (mm)

L

0.88

75–100

5.0

0.77

71

100

100

46

Celiac (mm)

L

0.93

85–100

2.6

0.87

87

86

95

67

Paralysis

Height difference (cm)

R

1.00

100–100

4.4

1.00

100

100

100

100

Paralysis

Height difference (cm)

L

0.98

94–100

2.7

0.95

88

100

100

93

Weakness

Height difference (cm)

R

1.00

100–100

3.5

1.00

100

100

100

100

Weakness

Height difference (cm)

L

0.79

56–100

2.5

0.88

71

93

71

93

  1. R Right, L Left, AUC area under the curve, 95%CI 95% confident interval, Se sensitivity, Spe specificity, PPV positive predictive value, NPV negative predictive value
  2. Threshold values of CT-scan measurements to diagnose diaphragm dysfunction (ultrasound as reference) at the level of the celiac artery or L1 (mm) and of the height difference (cm)