Skip to main content

Table 2 Respiratory parameters at selected CDP

From: Oscillometry for personalizing continuous distending pressure maneuvers: an observational study in extremely preterm infants

 

CDPi

CDPXrs

CDPOpt_SpO2

CDPf

CDP, cmH2O

10.5 (9.5; 12.0)

[7–13]

9.0 (8.0; 11.0)

[5–20]

10.0 (9.0; 11.5)

[7–14]

10.0 (9.0; 11.5)

[7–14]

SpO2/FiO2

1.64 (1.08; 2.15)

[0.86–3.46]

2.46 (1.95; 3.17)*

[0.98–4.24]

2.56 (1.69; 3.13)*

[1.04–4.38]

2.57 (1.95; 3.13)*

[1.11–4.48]

FiO2

55 (42; 82)

[26–100]

37 (30; 50)*

[21–90]

35 (30; 54)*

[21–90]

35 (30; 47)*

[21–85]

Xrs, cmH2O*s/L

-66.1 (-76.7; -56.5)

[-140.2 – -27.2]

-39.0 (-52.9; -29.3)*

[-82.8 – -11.8]

-47.2 (-56.5; -33.8)*°

[-99.7 – -18.5]

-47.7 (-61.3; -35.9)*°

[-93.4 – -13.4]

OSI, cmH2O

6.77 (5.05; 8.86)

[2.90–13.95]

3.94 (3.15; 5.47)*

[3.15–5.47]

4.22 (3.23; 5.54)*

[3.23–5.54]

4.27 (3.30; 5.64)*

[2.01 – 9.04]

  1. CDPi = initial CDP of the maneuver; CDPf = final CDP at the end of the procedure, after re-recruitment after the deflation limb; CDPOpt_SpO2 = optimal CDP as identified by oxygenation; CDPXrs = the CDP providing maximal Xrs on the deflation limb. Data are reported as median (interquartile range) [range]