Table 2 Pearson correlation coefficients indicating the strength and direction of the relationship between the actual ΔP and baseline lung compliance or baseline PF ratio for different APRV settings

From: Validation of at-the-bedside formulae for estimating ventilator driving pressure during airway pressure release ventilation using computer simulation

 

Correlation coefficient

Actual ΔPadult vs Compliance

Phigh = 25 Plow = 0

0.00

Actual ΔPadult vs Compliance

Phigh = 30 Plow = 0

− 0.11

Actual ΔPadult vs Compliance

Phigh = 30 Plow = 5

− 0.07

Actual ΔPadult vs PF ratio

Phigh = 25 Plow = 0

− 0.12

Actual ΔPadult vs PF ratio

Phigh = 30 Plow = 0

− 0.19

Actual ΔPadult vs PF ratio

Phigh = 30 Plow = 5

− 0.07

  1. The correlation coefficients were found to not be statistically significant (p < 0.05)