Skip to main content

Table 3 Sensitivity and specificity and AUC of 5 identified miRNAs in detecting early-stage NSCLC

From: Five microRNAs in plasma as novel biomarkers for screening of early-stage non-small cell lung cancer

MiRNA

Training set (NSCLC vs. Healthy)

Validation set (NSCLC vs. Control)

Sensitivity (95% CI)

Specificity (95% CI)

AUC (95% CI)

Sensitivity (95% CI)

Specificity (95% CI)

AUC (95% CI)

miR-20a

0.84 [0.76-0.90]

0.83 [0.71-0.92]

0.91 [0.86-0.95]

0.83 [0.74-0.89]

0.81 [0.72-0.88]

0.89 [0.85-0.93]

miR-223

0.87 [0.80-0.93]

0.86 [0.75-0.94]

0.96 [0.94-0.98]

0.87 [0.80-0.92]

0.86 [0.78-0.92]

0.94 [0.91-0.96]

miR-21

0.70 [0.61-0.78]

0.68 [0.55-0.80]

0.79 [0.73-0.86]

0.67 [0.54-0.72]

0.68 [0.59-0.77]

0.77 [0.71-0.83]

miR-155

0.87 [0.80-0.93]

0.87 [0.75-0.94]

0.94 [0.91-0.97]

0.86 [0.78-0.91]

0.84 [0.76-0.91]

0.92 [0.89-0.96]

miR-145

0.73 [0.64-0.81]

0.75 [0.62-0.85]

0.82 [0.75-0.88]

0.70 [0.61-0.78]

0.68 [0.58-0.76]

0.77 [0.71-0.83]