Skip to main content

Table 3 Annual rates of decline in pre-/post-bronchodilator IC, FEV 6 , and SVC over 4 years a

From: Longitudinal inspiratory capacity changes in chronic obstructive pulmonary disease

 

Tiotropium (mL/year)

Control (mL/year)

Δ Tiotropium–control

p-value

N

Mean (SE)

N

Mean (SE)

Mean (SE)

 

Pre-bronchodilator

2910

36 (3)

2864

32 (3)

5 (5)

0.30

Post-bronchodilator

2905

52 (4)

2853

47 (4)

6 (5)

0.28

Pre-bronchodilator

2910

42 (2)

2864

40 (2)

2 (3)

0.39

Post-bronchodilator

2905

57 (2)

2853

57 (2)

−0 (3)

0.91

Pre-bronchodilator

2531

47 (3)

2374

41 (3)

6 (4)

0.11

Post-bronchodilator

2527

66 (3)

2383

65 (3)

1 (4)

0.79

  1. aData from SVC previously published [13].
  2. Abbreviations: FEV6, forced expiratory volume in 6 seconds; IC, inspiratory capacity; SE, standard error; SVC, slow vital capacity.