Skip to main content

Table 3 Forced Oscillation Technique parameters before and after Bronchial Thermoplasty treatment

From: Resistance of the respiratory system measured with forced oscillation technique (FOT) correlates with bronchial thermoplasty response

 

Parameter

Before BT

After BT

P-value

Before bronchodilation

Rrs 5 Hz (cm H2O*s/L)

3.58 (3.21; 4.24)

3.70 (2.88; 4.29)

0.59

Xrs 5 Hz (cm H2O*s/L)

−1.23 (−1.68; −0.89)

−1.28 (− 1.81; − 0.95)

0.21

Rrs 19 Hz (cm H2O*s/L)

3.17 (2.85; 3.56)

3.15 (2.80; 3.67)

0.95

Xrs 19 Hz (cm H2O*s/L)

0.65 (0.09; 0.99)

0.63 (−0.04; 0.80)

0.22

After bronchodilation

Rrs 5 Hz (cm H2O*s/L)

3.06 (2.73; 3.41)

3.22 (2.78; 3.63)

0.08

Xrs 5 Hz (cm H2O*s/L)

−1.00 (−1.15; −0.77)

−0.92 (− 1.23; − 0.73)

0.28

Rrs 19 Hz (cm H2O*s/L)

2.90 (2.65; 3.09)

2.97 (2.72; 3.47)

0.26

Xrs 19 Hz (cm H2O*s/L)

0.80 (0.56; 1.07)

0.87 (0.27; 1.08)

0.21

  1. Data are presented as median (IQR); n = 22 for pre-bronchodilator measurements and n = 23 for post-bronchodilator measurements
  2. Rrs respiratory resistance, Xrs reactance