Skip to main content

Table 4 Results of receiver operating characteristic curve analyses for mean nocturnal SpO2, time spent with SpO2 < 90% and morning PaCO2 for the detection of inappropriate NIV (according to strategy D)

From: Monitoring of noninvasive ventilation: comparative analysis of different strategies

 

Threshold

Sensitivity (%)

Specificity (%)

Positive likelihood ratio

Negative likelihood ratio

Mean nocturnal SpO2 (%)

88

7.1

100

1.08

1

90

32.4

100

4.38

0.69

92

45.9

91.7

5.51

0.59

94

71.6

70.8

2.46

0.40

96

90.5

29.2

1.28

0.32

Time spent with SpO2 < 90% (% of total recording time)

5

63.5

95.8

15.24

0.38

20

43.2

95.8

10.38

0.59

30

43.2

100

 

0.57

Morning PaCO2 (mmHg)

42

69.9

90.9

7.68

0.33

45

50.7

95.4

14.16

0.37

48

36.2

100

 

0.64

  1. PaCO2 arterial carbon dioxide partial pressure, SpO2 transcutaneous pulsed oxygen saturation