Skip to main content

Table 1 Oxygenation index and static compliance in vivo and during EVLP

From: Cellular and acellular ex vivo lung perfusion preserve functional lung ultrastructure in a large animal model: a stereological study

Time point

Group

OI

Cstat [l/kPa]

In vivo

Control

520 ± 91

0.66 ± 0.17

Ischaemia

487 ± 87

0.52 ± 0.14

aEVLP

496 ± 64

0.65 ± 0.10

cEVLP

469 ± 10

0.64 ± 0.19

2 h EVLP

aEVLP

482 ± 41

0.86 ± 0.12

cEVLP

506 ± 55

0.76 ± 0.27

12 h EVLP

aEVLP

496 ± 41

0.57 ± 0.08

cEVLP

514 ± 61

0.55 ± 0.12

  1. Mean ± SD. In vivo data were obtained post thoracotomy immediately before lung explantation. Data of 2 and 12 h EVLP were obtained after 24 h cold ischemia and 2 and 12 h EVLP, respectively. Data of aEVLP and cEVLP groups were taken from [15]. OI did not differ significantly between groups (p = 0.912) or time points (p = 0.557). Cstat was not significantly different between groups (p = 0.549) but differed significantly between all 3 time points for EVLP groups (p = 0.004). OI oxygenation index at FiO2 = 1, Cstat static lung compliance