Figure 2

Scatterplots (Bland-Altman). On the left, the difference between measured maximum exercise capacity (W peak) measured by incremental cycle test (ICT) and estimated W peak from performance on incremental shuttle walking test (ISWT) against the mean values of those two. On the right, the difference between measured W peak from ICT and estimated W peak from measured maximum oxygen uptake on semi steady-state cardiopulmonary exercise test (CPET) [16] against the mean of those two. Whole line: mean difference, dotted lines: ± 2SD.