Figure 3 | Respiratory Research

Figure 3

From: Fractal ventilation enhances respiratory sinus arrhythmia

Figure 3

Calculation of Respiratory Sinus Arrhythmia (RSA). Computer generated strip chart recording from data acquisition system showing how respiratory sinus arrhythmia (RSA) was determined during mechanical ventilation. Top panel – delivered tidal volume (millilitres), middle panel – inspiratory and expiratory flow, bottom panel – electrocardiogram (ECG). Below each heartbeat is the time in milliseconds (msec) of the beat interval. If the preceding beat was initiated in inspiration then this beat interval was considered to have occurred during inspiration and vice versa for expiration. In this respiratory cycle the RSA was positive at 120 msec (817 – 697 msec).