Skip to main content

Table 1 Baseline values for respiratory parameters from allergic and control BALB/c mice

From: Invasive versus noninvasive measurement of allergic and cholinergic airway responsiveness in mice

Respiratory parameters

Definition

Control mice conscious

Allergic mice conscious

Control mice anesthetized

Allergic mice anesthetized

VT, ml

tidal volume

0.21 ± 0.05

0.19 ± 0.04

0.14 ± 0.02

0.13 ± 0.02

f, breaths/min

respiratory frequency

198 ± 41

220 ± 23

129 ± 20*

124 ± 29*

TE, s

time of expiration

0.17 ± 0.06

0.14 ± 0.02

0.3 ± 0.04*

0.3 ± 0.05*

EF50, ml/s

tidal midexpiratory flow

2.05 ± 0.89

2.26 ± 0.46

0.93 ± 0.14*

1.12 ± 0.43*

GL, ml·s-1·cmH2O-1

pulmonary conductance

-

-

1.05 ± 0.36

1.29 ± 0.69

Cdyn, ml·cmH2O-1

dynamic compliance

-

-

0.037 ± .007

0.030 ± .008

  1. Baseline values are means ± SD obtained from 8 animals per group during a 5 min control period from conscious and anesthetized, orotracheally intubated BALB/c mice. In comparison with conscious mice, EF50, TE and f values were significantly altered in anesthetized mice. No difference was found between allergic animals and control groups when separated into conscious and anesthetized mice. *P < 0.05 versus conscious mice.